A single plate shear connection, or shear tab, is a very popular shear connection due to its merit in ease of construction and material economy. However, problems in understanding the connection behavior, both in terms of strength and ductility, have been well-documented. Suggestions or design model for single plate connections in AISC Design Manual have been altered several times, with the latest edition settling down to giving designers pre-calculated design strength tables if the connection details agree with given configurations. Results from many full-scale tests and finite element models in the past suggest that shear strength of a bolt group in single plate shear connections might be affected by yield strength of plate material;;therefore, this research was aimed to investigate and clarify effects of plate yield strength and thickness on shear strength of the bolt group in the connections, including the validity of using a plate thickness/bolt diameter ratio (t_p/d_b) in design, by using finite element models. More than 20 models have been created by using ABAQUS program with 19.0- and 22.2-mm A325N bolts and A36 and Gr.50 plates with various thicknesses. Results demonstrated that increase of plate thickness or plate yield strength, with the t_p/d_b ratio remained intact, could significantly reduce shear strength of the bolt group in the connection as much as 15 percent. Results also confirmed that the t_p/d_b ratio is a valid indicator to be used for guaranteeing strength sufficiency. Because the actual ratio recommended by AISC Design Manual is t_p/d_b + 1.6 (mm) for connections with a number of bolts less than six and plate yield strength in construction is normally higher than the nominal value used in design, it is proposed that shear strength of a bolt group in single plate connections with a number of bolts equal or greater than seven be reduced by 15 percent and the t_p/d_b ratio be limited to 0.500.
机译:单板剪切连接或剪切片是一种非常流行的剪切连接,因为它具有易于构造和材料经济的优点。但是,关于强度和延展性方面的理解连接行为的问题已得到了很好的记录。 AISC设计手册中有关单板连接的建议或设计模型已进行了多次更改,如果连接的详细信息与给定的配置相吻合,则最新版本的版本将逐步提供给设计人员预先计算的设计强度表。过去许多全尺寸试验和有限元模型的结果表明,单板剪切连接中螺栓组的剪切强度可能会受到板材料屈服强度的影响;因此,本研究旨在研究和弄清螺栓的作用。板屈服强度和厚度对连接中螺栓组的抗剪强度的影响,包括使用有限元模型在设计中使用板厚/螺栓直径比(t_p / d_b)的有效性。通过使用ABAQUS程序,使用19.0毫米和22.2毫米的A325N螺栓以及厚度不同的A36和Gr.50板,已经创建了20多个模型。结果表明,在t_p / d_b比例保持不变的情况下,增加板厚度或板屈服强度可以显着降低连接中螺栓组的剪切强度达15%。结果还证实,t_p / d_b比是用于保证强度足够的有效指标。由于AISC设计手册建议的实际比率是t_p / d_b + 1.6(mm),用于螺栓数量少于六个的连接,并且建筑中的板屈服强度通常高于设计中使用的标称值,因此建议采用剪切数量等于或大于七个的单板连接中的螺栓组的强度降低15%,并且t_p / d_b比率限制为0.500。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号