The objective of this research is to study the ultimate moment capacity of the connections between steel I-beams and concrete-filled steel tube columns using different stiffener configurations. The main parameters considered are column cross section shape, square or circular, and filling the column with concrete. This analytical study includes finite element models using ANSYS program taking geometric and material nonlinearities into consideration. These models are verified against the experimental results obtained from previous researches and current design guides. The results show that using proper stiffener configuration affects the stress distribution through the connection and increases the ultimate moment capacity of the connections. Also, circular column is advantageous than the square column for all stiffener configurations and dimensions.
机译:这项研究的目的是研究使用不同的加强筋配置的工字钢和钢管混凝土柱之间连接的极限弯矩能力。考虑的主要参数是圆柱的横截面形状,正方形或圆形,以及用混凝土填充圆柱。该分析研究包括使用ANSYS程序的有限元模型,其中考虑了几何和材料非线性。这些模型已根据先前研究和最新设计指南获得的实验结果进行了验证。结果表明,使用适当的加强筋配置会影响连接处的应力分布,并增加连接处的极限弯矩承载力。同样,对于所有的加劲肋结构和尺寸,圆柱比方柱更有优势。