首页> 外文期刊>Engineering Structures >Cyclic loading tests of interior beam-column connections for concrete-filled thin-walled tube columns
【24h】

Cyclic loading tests of interior beam-column connections for concrete-filled thin-walled tube columns

机译:混凝土薄壁管柱内部梁柱连接的循环荷载试验

获取原文
获取原文并翻译 | 示例

摘要

In this study, the results of the cyclic loading tests of four interior connection specimens made of concrete-filled thin-walled tube column and U-section beam are presented. Through-beams and through-bars passing through the column were used as the connection details. The tests showed that both slip significantly occurred during cyclic loading and thus the strength, ductility, and energy dissipation capacity of the specimens were significantly affected by the connection details. The web plates of the beam U-section, which were welded to the thin column tube wall, did not fully contribute to the connection strength, due to out-of-plane deformation and premature weld fracture of the tube wall plates. Based on the test results, a modified plastic stress distribution method to estimate the connection strength was suggested. In addition, design and detailing considerations of the proposed through-beam and through-bar connection details are given.
机译:在这项研究中,给出了四个内部连接标本的循环荷载试验结果,这些标本由混凝土填充的薄壁管柱和U型截面梁制成。通过柱的直通梁和直通杆用作连接详细信息。测试表明,在循环荷载作用下,两种滑移都明显发生,因此,连接细节对试样的强度,延展性和能量耗散能力有显着影响。由于管壁板的平面外变形和过早的焊接断裂,被焊接到薄柱管壁上的横梁U型截面腹板并没有完全有助于连接强度。根据测试结果,提出了一种改进的塑性应力分布方法来估算连接强度。此外,还给出了所建议的通孔和直通杆连接细节的设计和详细考虑。