首页> 外文期刊>Surgical Endoscopy >Dedicated minimally invasive surgery suites increase operating room efficiency.
【24h】

Dedicated minimally invasive surgery suites increase operating room efficiency.

机译:专用的微创手术套件可提高手术室效率。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: The rapid adoption of laparoscopic surgery since the late 1980s added tremendous complexity into the operating room (OR) environment. For each case, a plethora of additional equipment-including monitors, video equipment, wiring, tubing, and cords-had to be set up, prolonging OR turnover time and decreasing OR efficiency. In 1993, the concept of designated minimally invasive surgery (MIS) suites was introduced. MIS suites integrated monitors and video equipment into the OR on ceiling-mounted columns and moved the controls to a centralized nursing station. The overall effect of this innovation on OR efficiency has not been measured. METHODS: Five RNs with varying degrees of MIS experience were instructed on video setup and put-away criteria and then timed while performing a set of standardized tasks. Each set of tasks was performed twice using a standardized surgery model. Differences in setup and put-away times between MIS suites and standard ORs were tested using the t-test for paired comparisons. RESULTS: The mean +/- standard deviation (SD) video setup times were 27.9 +/- 5.3 sec (MIS) and 254.3 +/- 54.0 sec (standard); the put-away times were 19.8 +/- 2.7 sec (MIS) and 222.3 +/- 26.0 sec (standard). The mean difference +/- standard error (SE) in both the setup (226.4 +/- 16.9 sec, p = 0.0001) and put-away times (202.5 +/- 8.6, p = 0.0001) were large and statistically significant. CONCLUSION: Using a simulation model, we have demonstrated that the use of a MIS suite reduces video setup and put-away time significantly, with the potential for significant associated cost savings. This provides just one justification for the high cost of building such "ORs of the future."
机译:背景:自1980年代后期以来,腹腔镜手术的迅速采用为手术室(OR)环境增加了极大的复杂性。对于每种情况,都必须设置大量额外的设备,包括监视器,视频设备,布线,管道和电线,这会延长OR转换时间并降低OR效率。 1993年,引入了指定的微创手术(MIS)套件的概念。 MIS套件将监视器和视频设备集成到吊装柱上的OR中,并将控件移至集中式护理站。尚未测量这种创新对OR效率的总体影响。方法:对五位具有不同MIS经验经验的RN进行视频设置和发布标准的指导,然后在执行一组标准化任务时进行计时。使用标准化手术模型,每组任务执行两次。使用t检验对配对套件的MIS套件和标准OR之间的设置和上架时间的差异进行了测试。结果:平均+/-标准差(SD)视频设置时间为27.9 +/- 5.3秒(MIS)和254.3 +/- 54.0秒(标准);投放时间为19.8 +/- 2.7秒(MIS)和222.3 +/- 26.0秒(标准)。设置(226.4 +/- 16.9秒,p = 0.0001)和上架时间(202.5 +/- 8.6,p = 0.0001)的平均差+/-标准误差(SE)很大,并且具有统计意义。结论:使用仿真模型,我们已经证明,使用MIS套件可以显着减少视频设置和上架时间,并有可能节省大量相关成本。这仅为构建此类“未来OR”的高成本提供了一个理由。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号