首页> 外文期刊>Spectrochimica Acta, Part B. Atomic Spectroscopy >Determination of hydride forming elements (As,Sb,Se,Sn) and Hg in environmental reference materials as acid slurries by on-line hydride generation inductively coupled plasma mass spectrometry
【24h】

Determination of hydride forming elements (As,Sb,Se,Sn) and Hg in environmental reference materials as acid slurries by on-line hydride generation inductively coupled plasma mass spectrometry

机译:在线氢化物发生-电感耦合等离子体质谱法测定酸性浆液中环境参考物质中的氢化物形成元素(As,Sb,Se,Sn)和Hg

获取原文
获取原文并翻译 | 示例
           

摘要

A method for the determination of As,Hg,Sb,Se and Sn in environmental and in geological reference materials,as acidified slurries,by flow injection (FI) coupled to a hydride generation system (HG) and detection by inductively coupled plasma mass spectrometry (ICP-MS) is proposed.The HG unit has a gas liquid separator and a drying unit for the generated vapor.The slurries were prepared by two procedures.Approximately 50 mg of the reference material,ground to a particle size <=50 mum,was mixed with acid solutions in an ultrasonic bath.In Procedure A,the medium was a hydrochloric acid solution while in Procedure B,the medium was aqua regia plus a hydrochloric acid solution.The conditions for the slurry formation and the instrumental parameters were optimized.Harsh conditions were used in the slurry preparation in order to reduce the hydride forming analytes to their lower oxidation states,As (III),Se(IV),Sb(III) and Sn(II),before reacting with sodium tetrahydroborate.To test the accuracy,10 certified reference materials were analyzed (four sediments,three coals,one coal fly ash and two sewage sludges),with the analyte concentrations mostly in the mug g~(-1) level.Good agreements with the certified values were obtained for Hg,Sb and Sn in the sediments using Procedure A and calibration against aqueous standard solutions.Using Procedure B,good results were obtained for Hg,Se and Sn in the sediment samples,for Se in the coal and coal fly ash samples and for Hg in the sewage sludge samples,also using external calibration with aqueous standard solutions.For As in sediments,coals and coal fly ash,Procedure B and the analyte addition calibration was required,indicating matrix effects.The relative standard deviations were lower than 5%,demonstrating a good precision for slurry analysis.The limits of quantification (10 times the standard deviation; n=10),in the samples,in ng g~(-1),were: 20 for As,60 for Hg,80 for Sb,200 for Se and 90 for Sn.The method requires small amounts of reagents and reduces contamination and losses.
机译:通过与氢化物发生系统(HG)耦合的流动注射(FI)并通过电感耦合等离子体质谱检测法测定环境和地质参考材料中酸化浆液中As,Hg,Sb,Se和Sn的方法(ICP-MS)建议方案.HG单元具有气液分离器和产生蒸汽的干燥单元。通过两种步骤制备浆料。约50 mg的参考物质,研磨至粒径<= 50微米在超声浴中与酸性溶液混合。在步骤A中,介质为盐酸溶液,而在步骤B中,介质为王水加盐酸溶液。优化了浆液形成条件和仪器参数在苛刻的条件下使用浆液进行制备,以便在与四氢硼酸钠反应之前将形成氢化物的分析物还原为较低的氧化态,即As(III),Se(IV),Sb(III)和Sn(II)。测试准确性分析了10种认证参考物质(四种沉积物,三种煤,一种煤粉煤灰和两种污水污泥),分析物浓度大多在杯子g〜(-1)级之间。使用步骤A并用标准水溶液校准沉淀物中的Sb和Sn。使用步骤B获得的沉淀物样品中的Hg,Se和Sn,煤和粉煤灰样品中的Se以及样品中的Hg均获得良好的结果污水污泥样品,也使用水溶液标准溶液进行外部校准。对于沉积物,煤和粉煤灰中的砷,需要步骤B和分析物添加校准,表明基质效应。相对标准偏差低于5%,表明浆液分析精度高。定量极限(标准偏差的10倍; n = 10),样品中ng g〜(-1)为:砷20,汞60,锑80,硒200,锡90.该方法需要少量试剂,减少了污染和损失。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号