首页> 外文期刊>Sports health >Reliability of a New Stabilized Dynamometer System for the Evaluation of Hip Strength
【24h】

Reliability of a New Stabilized Dynamometer System for the Evaluation of Hip Strength

机译:新型稳定测功机系统用于评估髋关节强度的可靠性

获取原文
获取原文并翻译 | 示例
       

摘要

Background: Hip strength is associated with numerous orthopaedic and neuromuscular injuries and/or pathologies and may be assessed with a variety of anatomic testing positions and techniques. Isokinetic dynamometers are generally too cumbersome and intricate for efficient use in mass screenings (for prognostic studies of risk for injury) as well as with special populations. The reliability of isometric testing devices has demonstrated varied reliability, generally examining only 1 or 2 motions of the hip and reporting values of force, not torque. Consequently, there is a need for an efficient hip strength-testing device to quantify torque that tests subjects in 1 anatomic position, while evaluating multiple hip motions. Hypothesis: Evaluation of supine hip abduction, adduction, flexion, and extension torque using a new stabilized dynamometer system will produce good to excellent intra- and interexaminer reliability results. Study Design: A blinded, randomized, repeated-measures study design was used in this descriptive laboratory investigation. Methods: Supine isometric hip flexion, extension, abduction, and adduction torques were evaluated with a cage-stabilized dynamometer in 19 collegiate and professional-level ice hockey athletes by 2 investigators at 3 time intervals. Inter- and intrarater reliability was assessed. Results: Supine hip flexion, extension, abduction, and adduction torque was performed with good to excellent inter- and intrarater reliability (intraclass correlation coefficients ranging from 0.74 to 0.92 and 0.78 to 0.92, respectively) for all motions tested. Conclusions: We have developed an isometric hip strength-testing device that can be assembled around an examination table to efficiently and reliably evaluate torque developed for multiple motions of the hip. Clinical Relevance: This device and testing protocol may be used to efficiently evaluate hip strength in numerous settings; it allows decreased subject burden and increased comfort (which may be important following an injury in case-control investigations); and it may be well tolerated when testing athletes as well as special populations in the clinical setting.
机译:背景:髋关节强度与多种骨科和神经肌肉损伤和/或病理相关,可以通过各种解剖学测试位置和技术进行评估。等速测力计通常太笨重且复杂,以致不能有效地用于大规模筛查(用于损伤风险的预后研究)以及特殊人群。等距测试设备的可靠性已显示出各种可靠性,通常仅检查髋部的1或2个运动并报告力值,而不报告扭矩值。因此,需要一种有效的髋部强度测试装置,以量化在1个解剖位置测试受试者的扭矩,同时评估多个髋部运动。假设:使用新型稳定的测力计系统评估仰卧位髋关节外展,内收,屈曲和伸展扭矩,将产生良好到极好的内部和内部检查者可靠性结果。研究设计:在此描述性实验室研究中,使用了盲法,随机,重复测量的研究设计。方法:由两名调查员在3个时间间隔内,对19名大学和专业水平的冰球运动员进行笼式测力计,评估其仰卧等距髋关节的屈曲,伸展,外展和内收扭矩。评价者之间和评价者内部的可靠性。结果:所有测试动作的仰卧髋关节屈曲,伸展,外展和内收扭矩均具有良好至极好的评估者之间和评估者内部可靠性(组内相关系数分别为0.74至0.92和0.78至0.92)。结论:我们开发了一种等距的髋部力量测试设备,该设备可以组装在检查台周围,以高效,可靠地评估针对髋部多种运动而产生的扭矩。临床意义:该设备和测试规程可用于在多种情况下有效评估髋关节强度。它可以减轻受试者的负担并提高舒适度(在病例对照研究中受伤后可能很重要);在临床环境中对运动员以及特殊人群进行测试时,可以很好地忍受。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号