首页> 外文期刊>Spine >Biomechanical analysis of multilevel fixation methods in the lumbar spine.
【24h】

Biomechanical analysis of multilevel fixation methods in the lumbar spine.

机译:腰椎多级固定方法的生物力学分析。

获取原文
获取原文并翻译 | 示例
           

摘要

STUDY DESIGN: The authors measured and compared the stiffness of cadaveric lumbar spines stabilized with several anterior interbody fusion devices. The information obtained provides a foundation for determining how methods of anterior lumbar fixation can maximize rigidity and promote development of bony fusion. OBJECTIVES: To compare the utility of three anterior spinal instrumentation systems for stabilizing the lumbar spine. SUMMARY OF BACKGROUND DATA: Anterior spinal instrumentation is used to prevent progressive spinal deformity and maintain correction after spinal fusion surgery. Newer instrumentation systems developed for anterior interbody fusions can be inserted by minimally invasive procedures. The stability of these systems has not been tested adequately in human cadaveric specimens. METHODS: Fusion constructs were evaluated in 12 human cadaveric specimens sequentially loaded in axial compression and torsion, flexion and extension, and lateral bending. The fusion constructs used were 1) two anterior bilateral threaded interbody fusion devices, 2) lateral hollow interbody screws (Texas Scottish Rite Hospital-B screws), and 3) femoral allograft and conventional anterior Texas Scottish Rite Hospital instrumentation. RESULTS: The construct with Texas Scottish Rite Hospital-B screws connected by a rod produced stiffness comparable with that produced by conventional Texas Scottish Rite Hospital instrumentation with femoral ring allografts. The threaded interbody fusion device stiffness tested in axial rotation was comparable with that achieved with Texas Scottish Rite Hospital instrumentation. CONCLUSIONS: Our data demonstrate the effectiveness of threaded interbody fusion device and the Texas Scottish Rite Hospital-B screw in immobilizing the L3-L4 and L4-L5 disc spaces. Rigidity of fixation in the lumbar spine may aid in the maintenance of lordosis.
机译:研究设计:作者测量并比较了几种前体椎间融合器稳定的尸体腰椎的刚度。获得的信息为确定前路腰椎固定方法如何最大程度地提高刚度并促进骨融合的发展提供了基础。目的:比较三种前路脊柱内固定系统在稳定腰椎中的实用性。背景数据摘要:脊柱前路器械用于预防进行性脊柱畸形并在脊柱融合手术后保持矫正。可以通过微创手术插入为前体椎间融合术开发的新型仪器系统。这些系统的稳定性尚未在人体尸体标本中进行充分测试。方法:在12个人体尸体标本中评估了融合结构,这些标本依次承受轴向压缩和扭转,弯曲和伸展以及横向弯曲。所使用的融合结构是:1)两个前侧双侧螺纹椎间融合器,2)侧向空心中空椎体螺钉(Texas Scottish Rite Hospital-B螺钉)和3)股骨同种异体移植物和传统的Texas Texas Rite Hospital以前的器械。结果:用杆连接德州苏格兰Rite Hospital-B螺钉的结构产生的刚度可与同种同种异体股指环移植的德州苏格兰Rite Hospital常规器械产生的刚度相媲美。在轴向旋转中测试的带螺纹的椎间融合器的刚度与使用德州苏格兰礼拜医院的仪器达到的刚度相当。结论:我们的数据证明了螺纹椎间融合器和德克萨斯州Rite Hospital-B螺钉在固定L3-L4和L4-L5椎间盘间隙中的有效性。腰椎固定的刚性可能有助于保持脊柱前凸。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号