首页> 外文期刊>Spine >Morphometric evaluation of lower cervical pedicle and its projection.
【24h】

Morphometric evaluation of lower cervical pedicle and its projection.

机译:下颈椎椎弓根的形态计量学评估及其投影。

获取原文
获取原文并翻译 | 示例
           

摘要

STUDY DESIGN: This study evaluated the lower cervical pedicle from C3 to C6 to provide information for accurate transpedicular screw fixation in this region. OBJECTIVES: To measure the dimensions of the lower cervical pedicle and to determine the correct location of the pedicle axis on the posterior aspect of the lateral mass. SUMMARY OF BACKGROUND DATA: Several anatomic studies and clinical applications of transpedicular screw fixation in the cervical spine have been documented, but little quantitative data concerning the lower cervical pedicle and its projection are available. METHODS: Forty dry cervical specimens from C3 to C6 (160 cervical vertebrae) were used for this study. Anatomic evaluation included pedicle height, width, effective length, and anguli. The distances from the projection point of the pedicle axis to reference lines related to the lateral edge of the lateral mass (vertical) and the inferior edge of the superior facet (horizontal) also were measured. The means, ranges, and standarddeviations were calculated for all of the specimens and separately for male and female spines. RESULTS: Statistically significant differences in dimensions of males and females were found in one linear and one angular measurement, which included the pedicle height of C6 and the pedicle sagittal angle of C4. The greatest variation for males and females was found in the pedicle sagittal angle, with a range of 4.3-9.8 degrees. The distances from the projection point to the horizontal line did not show any real pattern of change from C3 to C6, whereas the distances from the projection point to the vertical line consistently increased from cephalad to caudad. CONCLUSIONS: Taking into consideration some variations between individuals, this information, combined with evaluation of results of preoperative axial computed tomography and conventional radiography, may enhance the safety of transpedicular screw fixation in the lower cervical spine.
机译:研究设计:这项研究评估了从C3到C6的下颈椎椎弓根,以提供该区域的精确经椎弓根螺钉固定的信息。目的:测量下颈椎椎弓根的尺寸并确定椎弓根轴在侧块后方的正确位置。背景资料的总结:经颈椎椎弓根螺钉固定的一些解剖学研究和临床应用已有文献记载,但有关下颈椎椎弓根及其投影的定量数据很少。方法:本研究使用了40例从C3至C6的干燥宫颈标本(160枚颈椎)。解剖学评估包括椎弓根的高度,宽度,有效长度和小角度。还测量了从椎弓根轴线的投影点到与横向块的横向边缘(垂直)和上小平面的下边缘(水平)相关的参考线的距离。计算所有标本的平均值,范围和标准偏差,并分别计算雄性和雌性棘突。结果:在一次线性和一次角度测量中,男性和女性的尺寸存在统计学差异,其中包括椎弓根高度C6和椎弓根矢状位角C4。男性和女性的最大变异是在椎弓根矢状角上,范围在4.3-9.8度之间。从投影点到水平线的距离没有显示出从C3到C6的任何真实变化模式,而从投影点到垂直线的距离从头足到马尾始终增加。结论:考虑到个体之间的某些差异,该信息与术前轴向计算机断层扫描和常规X线摄影的结果评估相结合,可提高颈椎下椎椎弓根螺钉固定的安全性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号