首页> 外文期刊>Smart Materials & Structures >Monitoring of cement hydration using embedded piezoelectric transducers
【24h】

Monitoring of cement hydration using embedded piezoelectric transducers

机译:使用嵌入式压电传感器监测水泥水化

获取原文
获取原文并翻译 | 示例
       

摘要

The ultrasonic technique is very effective for non-destructive measurement of fresh and hardened cementitious composites. In this study, the ultrasonic technique is further developed with embedded piezoelectric transducers for cement paste hydration monitoring. In this method, the transducers were pre-placed in a mold before casting the specimen. After the specimen was cast, the transducers were used to generate and receive ultrasonic waves. Wave velocity and amplitude were measured. From the velocity measurement, the hydration process of cement paste could be interpreted. The interaction between the transducers and the cement paste was analyzed. In addition, the dynamic modulus was calculated using the wave velocity. Since the embedded transducers had good coupling with the cement paste, reliable test results have been obtained. It is feasible to use the technique as an in situ technique to monitor the hydration process at an early age, as well as the health condition after maturing for a concrete structure.
机译:超声技术对于新鲜和硬化的水泥基复合材料的非破坏性测量非常有效。在这项研究中,超声波技术通过嵌入式压电传感器进一步发展,用于水泥浆水化监测。在这种方法中,在铸造样品之前将换能器预先放置在模具中。浇铸样品后,使用换能器产生和接收超声波。测量波速和振幅。通过速度测量,可以解释水泥浆的水化过程。分析了换能器与水泥浆之间的相互作用。另外,使用波速来计算动态模量。由于嵌入式换能器与水泥浆具有良好的耦合,因此获得了可靠的测试结果。将该技术用作现场技术来监控早期的水化过程以及混凝土结构成熟后的健康状况是可行的。