Adsorption equilibrium data for CO, CO_2, CH_4 and C_2H_4 on 5A molecular sieve were obtained (303, 373 and 573) K and at partial pressures up to 1000 kPa. An accurate and simple volumetric apparatus was used to measure gas sorption. The Langmuir and Sips equations were used to correlate the experimental data. In spie of the relative simplicity of both isotherms, the correlation between experimental and theoretical data is good. The Sips equation with three parameters have expected a better fit than the Langmuir isotherm with two parameters. Based upon the Langmuir equation the enthalpy of adsorption and pre-exponential factor in the van't Hoff correlation were derived for all four gases.
机译:获得了在5A分子筛上(303、373和573)K且在分压高达1000 kPa的条件下CO,CO_2,CH_4和C_2H_4的吸附平衡数据。使用精确而简单的体积测量仪来测量气体吸收。 Langmuir和Sips方程用于关联实验数据。尽管两个等温线相对简单,但实验数据和理论数据之间的相关性很好。具有三个参数的Sips方程比具有两个参数的Langmuir等温线具有更好的拟合度。根据Langmuir方程,推导了所有四种气体的吸附焓和范特霍夫相关性中的指数前因子。