The Taguchi method was used to determine the optimum conditions for the phosphate removal from wastewater by electrocoagulation with aluminum plate electrodes.The experimental parameters investigated were initial phosphate concentration,initial pH of the wastewater,supporting electrolyte concentration,supporting electrolyte type and current density.The ranges of experimental parameters were between 50 and 500 mg/L (as PO_4-P),4-7 for initial pH,0-10 mM,NaCl,NaNO_3,Na_2SO_4 and CaCl_2 and 0.25-1.00 mA/cm~2 mm for initial phosphate concentration,initial pH of the wastewater,supporting electrolyte concentration,supporting electrolyte type and current density,respectively.Reaction period was kept constant in 25 min for statistical analysis.The optimum conditions for these parameters were found to be 50 mg/L,4,5 mM,NaCl and 1.00 mA/cm~2,respectively.Under these conditions,the predicted and experimental removal efficiency of phosphate from wastewater by electrocoagulation with aluminum plate electrodes were 99.9 and 100.0%,respectively.A statistical analysis of variance (ANOVA) was performed to see whether the process parameters were statistically significant or not.According to the F-test results,it can be concluded that the degrees of the influences of parameters on the removal efficiency is initial phosphate concentration,current density and initial pH of the solution.
机译:用Taguchi方法确定铝板电极电凝去除废水中磷酸盐的最佳条件。所研究的实验参数为初始磷酸盐浓度,废水的初始pH,支持的电解质浓度,支持的电解质类型和电流密度。实验参数范围为50至500 mg / L(以PO_4-P计),初始pH为4-7、0-10 mM,NaCl,NaNO_3,Na_2SO_4和CaCl_2和初始为0.25-1.00 mA / cm〜2 mm磷酸盐浓度,废水的初始pH值,支持的电解质浓度,支持的电解质类型和电流密度分别。反应时间在25分钟内保持恒定以进行统计分析。这些参数的最佳条件为50 mg / L,4分别为,5 mM,NaCl和1.00 mA / cm〜2。在这些条件下,铝板电凝从废水中去除磷酸盐的预测和实验效率电极分别为99.9%和100.0%。进行方差统计分析(ANOVA),以查看工艺参数是否具有统计学意义。根据F检验结果,可以得出结论:去除效率的参数是初始磷酸盐浓度,电流密度和溶液的初始pH。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号