The slender, thin film, K-type thermocouple, fabricated through sputtering deposition, is employed to probe the contact temperature of the frictional interfaces during the ultrasonic wire bonding process. This thin film sensor is of thickness of 1 mum and with three different fine widths that are 100, 80 and 20 mum, respectively. Contents of the sensor were demonstrated to be similar to the original K-type targets. Comparison of the thermoelectric relation of the sensor before and after the bonding processes ensured that the sensor operated appropriately during the bonding process. To help the analysis, modeling the temperature variation of the sensor based on a lumped system was also presented and discussed. Results show the currently fabricated sensor worked very well for the contact temperature measurement during the bonding process. For the same bonding condition, the recorded temperature increased with the reduction of the line width of the thermal sensor. The lumped system analysis indicated this increasing was mainly contributed by the reduction of the thermal inertia in the junction region that resulted from the decrease of the line width. With the advantage of the thin film thermal sensor, more sensitive and less invasive, the current measurement acquires temperature rise up 300 degreesC at the duration of bonding that, at least, is 150 degreesC higher than the available data in the literatures. Measurement result obtained by the present slender, thin film, thermal sensor is believed more close to true contact temperature. (C) 2003 Elsevier B.V. All rights reserved. [References: 19]
机译:通过溅射沉积制造的细长的薄膜K型热电偶用于探测超声引线键合过程中摩擦界面的接触温度。该薄膜传感器的厚度为1微米,并具有三个分别为100、80和20微米的不同精细宽度。传感器的内容被证明与原始K型目标相似。结合过程之前和之后的传感器热电关系的比较确保了传感器在结合过程中能够正常运行。为了帮助分析,还介绍并讨论了基于集总系统的传感器温度变化建模。结果表明,目前制造的传感器在粘接过程中对于接触温度的测量非常有效。对于相同的粘合条件,记录的温度随着热传感器线宽的减小而升高。集总系统分析表明,这种增加主要是由于线宽减小导致结区热惯性减小所致。凭借薄膜热传感器的优势,它具有更高的灵敏度和更小的侵入性,电流测量可在粘接期间使温度升高300摄氏度,至少比文献中的可用数据高150摄氏度。据信由本发明的细长的薄膜热传感器获得的测量结果更接近真实的接触温度。 (C)2003 Elsevier B.V.保留所有权利。 [参考:19]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号