OBJECTIVE: To document the preservation of hearing after electroacoustic (EAS) cochlear reimplantation and to report on a method of managing recurrent air accumulation under the posterior skin flap. STUDY DESIGN: Retrospective case report. PATIENTS: A single patient report. INTERVENTION: After successful EAS cochlear implantation with hearing preservation, patient developed recurrent air accumulation under his posterior flap and a subsequent device failure. The patient was reimplanted using EAS protocol and a myringotomy tube used to prevent reaccumulation of air. MAIN OUTCOME MEASURE: Preservation of hearing. RESULTS: Hearing was preserved after reimplantation, and air accumulation was avoided. CONCLUSION: Hearing can be preserved in EAS reimplantation using EAS surgical techniques. Air accumulation can be avoided or treated with a myringotomy tube.
机译:目的:记录电声(EAS)人工耳蜗植入后的听力保持情况,并报告管理后皮瓣下反复空气积聚的方法。研究设计:回顾性病例报告。患者:单例患者报告。干预:成功的EAS人工耳蜗植入并保留听力后,患者后皮瓣下反复出现空气积聚,继而发生器械故障。使用EAS方案将患者重新植入,并使用一根切开管以防止空气积聚。主要观察指标:保持听力。结果:再植入后可保留听力,避免空气积聚。结论:采用EAS手术技术可以保留EAS再植入的听力。可以避免空气积聚,或用一根切开毛细血管的导管治疗。