首页> 外文期刊>Oxidation Communications >STUDY ON A NOVEL PILOT SCALE VODF PROCESS OF BIOLOGICAL POLLUTANTS REMOVAL FOR DOMESTIC SEWAGE
【24h】

STUDY ON A NOVEL PILOT SCALE VODF PROCESS OF BIOLOGICAL POLLUTANTS REMOVAL FOR DOMESTIC SEWAGE

机译:新型生活污水生物污垢去除的先导规模VODF工艺研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Studying an efficient oxidation ditch (OD) process is still a popular topic in wastewater treatment plants (WWTPs). The study evaluated a pilot-scale novel saving energy and variable-velocity oxidation ditch with fine bubble (VODF) constructed in Xi'an 4th WWTP, which is used to enhance nutrient (nitrogen and phosphorus) removal. The pilot operated steadily at a treatment scale of about 50 m(3)/d for about 130 days. Activated sludge (AS) hydraulic performance by horizontal velocity (HV), structure character and dominant filamentous bacteria caused bulking and performing of nutrients removal were analysed. The results indicated that the novel OD can meet the requirement of saving energy under stable running state. Also the string effluent nutrient arrives at the first class in discharge standard of pollutants for municipal wastewater treatment plant (GB18918-2002). By changing ditch widths, different HVs in anoxic and aerobic zones of mixing activated sludge can be obtained. At the same time, the influence of the sludge structure on HV was studied in order to plan future ditch design and operation of aeration and compeller. According to our study, Microthrix parvicella was dominated filamentous bacteria causing limited bulking of AS. However, the polyporous structure captured the particle pollutants and improved effluent quality. Therefore, the concentrations of total chemical oxygen demand (TCOD), NH4+-N, total nitrogen (TN), total phosphorus (TP) and suspended solid (SS) of effluent were less than 50, 5, 15, 1 and 20 mg/1, respectively under the stable operations when SRT, HRT, DO concentrations at aeration bottom section, SS and water temperature were about 12-15 days, 11-15 h, 0.6-1.2 mg/l, 3000-5500 mg/l and 15-26 degrees C. The proposed VODF system was demonstrated to be an attractive enhanced biological nutrient removal process for WWTPs due to relatively high nutrient removal, robust sludge sediment and energy savings.
机译:在废水处理厂(WWTP)中,研究有效的氧化沟(OD)工艺仍然是一个热门话题。该研究评估了西安第四污水处理厂建造的中试规模的新型节能和带细气泡的可变速度氧化沟(VODF),该沟用于增强营养物(氮和磷)的去除。飞行员以约50 m(3)/ d的治疗规模稳定运行约130天。分析了由水平速度(HV)引起的活性污泥(AS)的水力性能,结构特征和主要的丝状细菌引起的膨胀以及去除营养物的性能。结果表明,该新型OD可以满足稳定运行状态下的节能要求。串式废水养分也达到了城市污水处理厂污染物排放标准的第一类(GB18918-2002)。通过改变沟渠宽度,可以在混合活性污泥的缺氧和好氧区域获得不同的HV。同时,研究了污泥结构对高压的影响,以计划将来的曝气沟和螺旋桨的设计和运行。根据我们的研究,Microthrix parvicella是占主导地位的丝状细菌,导致AS的体积有限。然而,多孔结构捕获了颗粒污染物并改善了废水质量。因此,废水的总化学需氧量(TCOD),NH4 + -N,总氮(TN),总磷(TP)和悬浮固体(SS)的浓度分别小于50、5、15、1和20 mg /如图1所示,在稳定运行条件下,曝气池底部的SRT,HRT,DO浓度,SS和水温分别约为12-15天,11-15小时,0.6-1.2 mg / l,3000-5500 mg / l和15 -26摄氏度。由于相对较高的养分去除率,强大的污泥沉积物和节能效果,拟议的VODF系统被证明是一种有吸引力的污水处理厂增强的生物养分去除方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号