首页> 外文期刊>Otology and neurotology: official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology >Comparison of the mechanical performance of ossiculoplasty using a prosthetic malleus-to-stapes head with a tympanic membrane-to-stapes head assembly in a human cadaveric middle ear model.
【24h】

Comparison of the mechanical performance of ossiculoplasty using a prosthetic malleus-to-stapes head with a tympanic membrane-to-stapes head assembly in a human cadaveric middle ear model.

机译:在人尸体中耳模型中,使用假体槌骨-sta骨钉头与鼓膜膜-head骨钉头组件的骨成形术的机械性能比较。

获取原文
获取原文并翻译 | 示例
           

摘要

HYPOTHESIS: Ossiculoplasty using prosthetic reconstruction with a malleus assembly to the stapes head will result in better transmission of vibrations from the eardrum to the stapes footplate than reconstruction with a tympanic membrane assembly to the stapes head. Both types of reconstruction will be affected by tension of the prosthesis. BACKGROUND: Theories (and some clinical studies) that the shape of the normal tympanic membrane is important suggest that prosthetic reconstruction to the malleus performs better than reconstruction to the tympanic membrane. This has not been previously tested by directly measuring vibration responses in the human ear. Our previous work suggests that tympanic membrane assembly to the stapes head type prostheses performed best under low tension. This had not been previously tested for malleus assembly to the stapes head type prostheses. METHODS: Hydroxyapatite prostheses were used to reconstruct a missing incus defect in a fresh cadaveric human ear model. Two types of prostheses were used, one from the stapes head to the malleus (malleus assembly to the stapes head), the other from the stapes head to the tympanic membrane (tympanic membrane assembly to the stapes head). Stapes footplate center responses were measured using a laser Doppler vibrometer in response to calibrated acoustic frequency sweeps. RESULTS: Tension had a very significant effect on both types of prostheses in the lower frequencies. Loose tension was best overall. The malleus assembly to the stapes head type prostheses consistently performed better than the tympanic membrane assembly to the stapes head type prostheses when stratified for tension. CONCLUSION: Tension has a significant effect on prosthesis function. Malleus assembly to the stapes head type prostheses generally result in better transmission of vibrations to the stapes footplate than tympanic membrane assembly to the stapes head type prostheses.
机译:假设:与通过鼓膜组件到sta骨头的重建相比,使用带有踝关节组件的骨重建术到the骨头的植骨术将导致更好的从鼓膜到foot骨足板的振动传递。两种类型的重建都将受到假体张力的影响。背景:正常鼓膜的形状很重要的理论(和一些临床研究)表明,对槌骨进行假体重建要比对鼓膜进行重建更好。以前尚未通过直接测量人耳的振动响应进行测试。我们以前的工作表明鼓膜到assembly骨头型假体的组装在低张力下效果最好。先前尚未测试过将​​其安装到mall骨头型假体的锤骨。方法:使用羟基磷灰石假体在新的尸体人耳模型中重建缺失的砧骨缺损。使用了两种类型的假体,一种是从pes骨头到槌骨(从小腿组件到the骨头),另一种是从the骨头到鼓膜(鼓膜组件到骨头)。使用激光多普勒振动计响应校准的声频扫描,测量骨踏板的中心响应。结果:张力在低频下对两种类型的假体都有非常显着的影响。松散的紧张感总体上最好。分层固定时,to骨头型假体的槌骨组件始终表现优于than骨头型假体的鼓膜组件。结论:张力对假体功能有重要影响。与向sta骨头型假体的鼓膜组件相比,与eu骨头型假体的槌骨组件通常导致更好地将振动传递到骨足板。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号