OBJECTIVE: The purpose of this study was to describe 2 unique cases of ocular motility dysfunction after powered endoscopic sinus surgery and identify potential risk factors for extraocular muscle injury. STUDY DESIGN: Interventional case series. RESULTS: Patient 1 developed a restrictive global ophthalmoplegia after inadvertent entry into the medial orbit during powered endoscopic sinus surgery. Patient 2 had complete loss of adduction of the left eye as a result of transection of the medial rectus muscle by a powered cutting instrument. CONCLUSIONS: Despite advances in endoscopic sinus surgery technique and instrumentation, serious ophthalmic complications may still occur. Inadvertent entry into the medial orbital wall can result in ocular motility complications. Furthermore, it is possible that attraction of orbital contents into the tip of a powered cutting instrument may occur without significant entry into the orbital cavity. SIGNIFICANCE: It is important for endoscopic sinus surgeons to be aware of the intimate anatomical relationship between the orbit and sinuses, as well as the potential risks of the current instruments used in endoscopic sinus surgery.
机译:目的:本研究的目的是描述2例内窥镜鼻窦手术后眼部运动功能障碍的独特病例,并确定引起眼外肌损伤的潜在危险因素。研究设计:介入病例系列。结果:患者1在动力性内窥镜鼻窦手术中无意进入眼眶内侧后出现局限性全眼肌麻痹。由于动力切割器械横切了内侧直肌,患者2的左眼内收完全丧失。结论:尽管内窥镜鼻窦手术技术和仪器有所进步,但仍可能发生严重的眼科并发症。意外进入眼眶内侧壁会导致眼球运动并发症。此外,有可能在没有明显进入轨道腔的情况下将轨道内容物吸引到动力切割器械的尖端中。意义:对于内窥镜鼻窦外科医生来说,重要的是要了解眼眶和鼻窦之间的紧密解剖关系,以及目前用于内窥镜鼻窦手术的仪器的潜在风险。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号