A risk assessment method was proposed to evaluate the evacuation safety in the collapse of a large steel structured gymnasium caused by localized fire. The criterion for safety evacuation was that the available evacuation time was greater than the required evacuation time, which could be determined by a proposed steel-temperature rise model and a proposed evacuation model, respectively. In the proposed steel-temperature rise model, not only the effects of smoke thermal radiation and convection, but also the effects of flame thermal radiation on steel components were considered. In the evacuation model, the required evacuation time was determined mainly by the following factors: distance from the farthest point to the safety exit, personnel evacuation speed, width of evacuation exit, and density of personnel. All these results and experimental data obtained in this study provide valuable references to fire simulation, hazard assessment, and fire protection design. (C) 2016 Elsevier Ltd. All rights reserved.
机译:提出了一种风险评估方法,以评估大型钢结构体育馆因局部失火而倒塌时的疏散安全性。安全疏散的标准是可用疏散时间大于所需疏散时间,这可以分别由提议的钢温升高模型和提议的疏散模型确定。在提出的钢温升高模型中,不仅考虑了烟气热辐射和对流的影响,还考虑了火焰热辐射对钢构件的影响。在疏散模型中,所需的疏散时间主要由以下因素决定:从最远点到安全出口的距离,人员疏散速度,疏散出口的宽度和人员密度。本研究中获得的所有这些结果和实验数据为火灾模拟,危害评估和消防设计提供了有价值的参考。 (C)2016 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号