...
首页> 外文期刊>Osteoarthritis and cartilage >Measurement properties of performance-based measures to assess physical function in hip and knee osteoarthritis: A systematic review
【24h】

Measurement properties of performance-based measures to assess physical function in hip and knee osteoarthritis: A systematic review

机译:基于性能的评估髋部和膝部骨关节炎身体功能的措施的测量特性:系统评价

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Objectives: To systematically review the measurement properties of performance-based measures to assess physical function in people with hip and/or knee osteoarthritis (OA). Methods: Electronic searches were performed in MEDLINE, CINAHL, Embase, and PsycINFO up to the end of June 2012. Two reviewers independently rated measurement properties using the consensus-based standards for the selection of health status measurement instrument (COSMIN). " Best evidence synthesis" was made using COSMIN outcomes and the quality of findings. Results: Twenty-four out of 1792 publications were eligible for inclusion. Twenty-one performance-based measures were evaluated including 15 single-activity measures and six multi-activity measures. Measurement properties evaluated included internal consistency (three measures), reliability (16 measures), measurement error (14 measures), validity (nine measures), responsiveness (12 measures) and interpretability (three measures). A positive rating was given to only 16% of possible measurement ratings. Evidence for the majority of measurement properties of tests reported in the review has yet to be determined. On balance of the limited evidence, the 40 m self-paced test was the best rated walk test, the 30 s-chair stand test and timed up and go test were the best rated sit to stand tests, and the Stratford battery, Physical Activity Restrictions and Functional Assessment System were the best rated multi-activity measures. Conclusion: Further good quality research investigating measurement properties of performance measures, including responsiveness and interpretability in people with hip and/or knee OA, is needed. Consensus on which combination of measures will best assess physical function in people with hip/and or knee OA is urgently required.
机译:目的:系统地评估基于性能的测量的测量属性,以评估髋部和/或膝部骨关节炎(OA)患者的身体功能。方法:截至2012年6月,在MEDLINE,CINAHL,Embase和PsycINFO中进行了电子搜索。两名评论者使用基于共识的标准选择健康状态测量仪器(COSMIN),对测量属性进行了独立评估。使用COSMIN结果和调查结果的质量进行了“最佳证据综合”。结果:在1792种出版物中,有24种符合纳入标准。评价了21个基于绩效的指标,包括15项单项活动指标和6项多项活动指标。评估的度量属性包括内部一致性(三个度量),可靠性(16个度量),测量误差(14个度量),有效性(九个度量),响应能力(12个度量)和可解释性(三个度量)。仅有可能的测量等级的16%给出了正面等级。评价中报告的大多数测试的测量特性的证据尚未确定。综合有限证据,40 m自定步速测试是最佳的步行测试,30 s椅站立测试和定时起跑测试是最佳的站立测试,Stratford电池,体力活动限制和功能评估系统是评分最高的多活动措施。结论:需要进行进一步的高质量研究,以研究绩效指标的测量特性,包括髋和/或膝骨关节炎患者的反应性和可解释性。迫切需要达成共识,即采取哪种措施才能最好地评估髋/膝膝盖骨关节炎患者的身体功能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号