首页> 外文期刊>Osteoarthritis and cartilage >Reproducibility of imaging human knee cartilage by delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at 1.5 Tesla.
【24h】

Reproducibility of imaging human knee cartilage by delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at 1.5 Tesla.

机译:通过延迟1.5特斯拉的g增强MRI软骨(dGEMRIC)成像人类膝盖软骨的重现性。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: The purpose of this study was to investigate the day-to-day reproducibility of the delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) measurement at different knee joint surfaces in healthy subjects at 1.5 Tesla (T). METHODS: The dGEMRIC experiment was repeated for 10 asymptomatic volunteers three times with an average interval of 5 days between scans. The measurement was performed from a single sagittal slice through the center of the lateral femoral condyle and from the center of the patella in the axial plane. Cartilage was manually segmented into superficial, deep and full-thickness regions of interests (ROIs) at different topographical locations of the femur, tibia and patella. The reproducibility was evaluated separately for each ROI as well as for the entire bulk cartilage in the slice of each joint surface. RESULTS: The reproducibility at various ROIs expressed by root-mean-square average coefficient of variation (CV(RMS)) ranged between 4.7-12.9%. Thirty out of thirty-three ROIs showed a CV(RMS) less than 10%. Intraclass correlation coefficient (ICC) ranged between 0.45 and 0.98. The CV(RMS) and ICC for bulk dGEMRIC were 4.2% and 0.95 for femur, 5.5% and 0.87 for tibia, and 4.8% and 0.97 for patella. CONCLUSIONS: The dGEMRIC technique showed good day-to-day reproducibility, on the average 8% for small deep or superficial segments, 7% for full-thickness ROIs and 5% for bulk ROIs covering all visible cartilage in a single joint surface. We conclude that dGEMRIC imaging at field strength 1.5 T can be used as a reliable instrument for the assessment of articular cartilage when staff has been carefully trained.
机译:目的:本研究的目的是研究健康受试者在1.5特斯拉(T)下在不同膝关节表面进行延迟d增强MRI(dGEMRIC)测量的每日重现性。方法:对10例无症状志愿者重复dGEMRIC实验3次,平均间隔为5天。测量是从单个矢状切面到股外侧lateral的中心,再从the骨中心在轴向平面上进行的。人工将软骨分为股骨,胫骨和骨的不同地形位置的浅表,深层和全层感兴趣区域(ROI)。对于每个ROI以及每个关节表面切片中的整个大块软骨,都分别评估了可重复性。结果:用均方根平均变异系数(CV(RMS))表示的各种ROI的重现性介于4.7-12.9%之间。在33个ROI中,有30个的CV(RMS)小于10%。类内相关系数(ICC)在0.45至0.98之间。整体dGEMRIC的CV(RMS)和ICC对于股骨分别为4.2%和0.95,对于胫骨为5.5%和0.87,对于骨为4.8%和0.97。结论:dGEMRIC技术具有良好的日常重现性,深部或浅表小段平均8%,全层ROI的平均7%,散装ROI的5%,覆盖单个关节表面的所有可见软骨。我们得出的结论是,经过认真培训的人员,场强为1.5 T的dGEMRIC成像可以用作评估关节软骨的可靠工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号