首页> 外文期刊>Operative dentistry >Prolonged curing time reduces the effects of simulated pulpal pressure on the bond strength of one-step self-etch adhesives.
【24h】

Prolonged curing time reduces the effects of simulated pulpal pressure on the bond strength of one-step self-etch adhesives.

机译:延长的固化时间可减少模拟纸浆压力对一步式自蚀刻胶粘剂粘合强度的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study was to evaluate the effects of extended light-curing procedures on the microtensile bond strength (μTBS) of one-step self-etch adhesives (1-SEAs) submitted to simulated pulpal pressure. Coronal deep-dentin specimens were bonded using Clearfil S3 Bond (S3), Adper Easy Bond (EB), or G-Bond Plus (GB) following the manufacturers' recommendations and light-cured for 10 seconds or 40 seconds. The dentin-bonded specimens were stored in distilled water for 24 hours without pulpal pressure (control) or submitted to 20 cm H2O simulated pulpal pressure for 24 hours. The specimens were cut into matchsticks and subjected to μTBS testing. The data were statistically analyzed using the three-way analysis of variance and Tukey's tests (p<0.05). Debonded sticks were investigated through scanning electron microscopy. EB obtained higher bond strengths than GB and S3. However, prolonged light activation (40 seconds) provided higher μTBS for all adhesives when submitted to pulpal pressure. Conversely, pulpal pressure caused a drop in μTBS in EB and S3 when light-cured for 10 seconds. A mixed failure mode was mainly attained for the control groups, whereas the specimens submitted to pulpal pressure failed in the adhesive mode. The μTBS of GB was not affected by pulpal pressure when light-cured for 10 seconds. Adhesive was the most prevalent failure mode, except when light-cured for 40 seconds, which showed predominantly cohesive failure. Extended curing times improved the resistance of 1-SEAs to simulated pulpal pressure.
机译:这项研究的目的是评估延长的光固化程序对单步自蚀刻胶粘剂(1-SEA)施加模拟牙髓压力的微拉伸粘合强度(μTBS)的影响。遵循制造商的建议,使用Clearfil S3 Bond(S3),Adper Easy Bond(EB)或G-Bond Plus(GB)将冠状深牙本质标本粘合在一起,然后光固化10秒或40秒。将粘合牙本质的样品在无牙髓压力的情况下在蒸馏水中保存24小时(对照),或者在20 cm H2O模拟牙髓压力下保存24小时。将样品切成火柴,并进行μTBS测试。使用三项方差分析和Tukey检验对数据进行统计分析(p <0.05)。通过扫描电子显微镜研究剥离的棒。 EB获得的结合强度高于GB和S3。但是,延长的光活化时间(40秒)在施加纸浆压力时为所有粘合剂提供了更高的μTBS。相反,光固化10秒后,纸浆压力导致EB和S3中的μTBS下降。对照组主要达到混合破坏模式,而经受牙髓压力的标本在粘合模式下破坏。 GB的μTBS在光固化10秒后不受纸浆压力的影响。胶粘剂是最普遍的破坏模式,除了光固化40秒时,主要表现为内聚破坏。延长固化时间可提高1-SEA对纸浆压力的抵抗力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号