Fixation properties of a biodegradable 'free-form' osteosynthesis plate with screws with cut-off screw heads: biomechanical evaluation over 26 weeks.

机译:带可切断螺钉头的螺钉的可生物降解“自由形式”骨合成板的固定特性:26周内的生物力学评估。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: The aim of this study was to compare the postoperative fixation properties of a biodegradable osteosynthesis "free-form" plate achieved with countersunk screws with those provided by screws with cut-off screw heads. STUDY DESIGN: Acrylic pipes were fixed together to simulate fracture fixation for tensile testing. Additional plates were fixed to a polyurethane block with a single screw for plate-screw pullout testing. Specimens were incubated in phosphate buffer solution at 37 degrees C, and testing was conducted at various time points during hydrolytic degradation of 26 weeks. In both tests the specimens were loaded at a speed of 5 mm/min until failure. The yield load, maximum load, and stiffness were recorded, and failure mode was visually determined. RESULTS: Both countersunk screws and screws with cut-off screw heads provided similar plate fixation properties over degradation time. CONCLUSION: According to these results, fixation of the biodegradable osteosynthesis free-form plate with screws with cut-off screw heads seems to be feasible.
机译:目的:本研究的目的是比较用埋头螺钉与可切除螺钉头螺钉提供的可生物降解的骨合成“自由形态”板的术后固定性能。研究设计:将丙烯酸管固定在一起以模拟断裂固定以进行拉伸测试。用单螺杆将另外的板固定到聚氨酯块上,以进行板螺钉拉出测试。将标本在磷酸盐缓冲液中于37℃孵育,并在26周的水解降解过程中的各个时间点进行测试。在这两个测试中,样品以5 mm / min的速度加载,直到失效。记录屈服载荷,最大载荷和刚度,并目视确定破坏模式。结果:沉头螺钉和带有切断螺钉头的螺钉在降解时间内都具有相似的板固定性能。结论:根据这些结果,用可切断螺钉头的螺钉固定可生物降解的骨合成自由形态板似乎是可行的。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号