摘要

The previously proposed method for noninvasively measuring the positions of elements in the human eye is further developed. A procedure for increasing the resolution of the method based on decreasing the discreteness of measurements is proposed and implemented in numerical experiments. For a system of two closely located phase screens, the resolution was increased 16-fold, which made it possible to determine the positions of the two screens. In order to resolve the positions of all optical elements, for the Gullstrand eye model, it was sufficient to increase the resolution and the Fourier filtration by a factor of four.
机译:进一步提出了先前提出的用于非侵入性地测量人眼中元素的位置的方法。提出了一种基于减小测量离散度来提高方法分辨率的程序,并在数值实验中实现了该程序。对于两个紧密放置的相位屏幕的系统,分辨率提高了16倍,这使得确定两个屏幕的位置成为可能。为了解析所有光学元件的位置,对于Gullstrand眼模型,将分辨率和傅立叶滤波提高四倍就足够了。