首页> 外文期刊>Optics & Laser Technology >Laser-induced damage of multilayer dielectric gratings with picosecond laser pulses under vacuum and air
【24h】

Laser-induced damage of multilayer dielectric gratings with picosecond laser pulses under vacuum and air

机译:真空和空气中皮秒激光脉冲对多层介质光栅的激光损伤

获取原文
获取原文并翻译 | 示例
           

摘要

In this study, laser damage tests of multilayer dielectric gratings (MDGs) are performed in vacuum (5 x 10(-4) Pa) and in air at a wavelength of 1053 nm with pulse widths of 0.56 Ps similar to 9.7 ps. The laser-induced damage threshold (LIDT) of MDGs in vacuum/air ranges from 2.1/2.2 J/cm(2) to 4.4/4.8 J/cm(2) for laser beams of normal incidence. The LIDT of MDGs follows a tau(0.26) scaling in the pulse width regime considered. The typical damage morphologies in the two environments caused by the near threshold pulse were observed using a scanning electron microscope (SEM); the results indicate that the damage features of MDGs in vacuum are the same as those in air. The testing results reveal that a clean vacuum environment neither changes the laser damage mechanism nor lowers the LIDT of MDGs. (C) 2015 Elsevier Ltd. All rights reserved.
机译:在这项研究中,多层介电光栅(MDG)的激光损伤测试是在真空(5 x 10(-4)Pa)和空气中以1053 nm的波长进行的,脉冲宽度为0.56 Ps,近似于9.7 ps。 MDG在真空/空气中的激光诱导损伤阈值(LIDT)在法向入射激光束的范围从2.1 / 2.2 J / cm(2)到4.4 / 4.8 J / cm(2)。 MDG的LIDT在所考虑的脉冲宽度范围内遵循tau(0.26)缩放比例。使用扫描电子显微镜(SEM)观察到了由接近阈值脉冲引起的两种环境中的典型损伤形态。结果表明,MDGs在真空中的破坏特征与在空气中相同。测试结果表明,清洁的真空环境既不会改变激光的损坏机制,也不会降低MDG的LIDT。 (C)2015 Elsevier Ltd.保留所有权利。