首页> 外文期刊>Ophthalmology >Visual acuity and contrast sensitivity in eyes implanted with aspheric and spherical intraocular lenses.
【24h】

Visual acuity and contrast sensitivity in eyes implanted with aspheric and spherical intraocular lenses.

机译:植入非球面和球面人工晶状体的眼睛的视敏度和对比敏感度。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To compare visual acuity and contrast sensitivity (CS) in eyes implanted with aspheric and spherical intraocular lenses (IOLs) after cataract surgery. DESIGN: Randomized, prospective study. PARTICIPANTS: Five hundred twenty-four eyes from 262 cataract surgery patients implanted with 2 IOL models: the AcrySof IQ (262 eyes) and AcrySof SN60AT (262 eyes; Alcon Laboratories, Fort Worth, TX). METHODS: High-contrast photopic best-corrected distance visual acuity (BCVA) and CS under photopic (85 cd/m(2)) and mesopic (6 cd/m(2)) conditions were measured. Pupil diameter was analyzed for distance vision under both lighting conditions. Follow-up was carried out for 6 months in all patients. MAIN OUTCOMES MEASURES: Best-corrected distance visual acuity and photopic and mesopic CS after implantation under monocular and binocular conditions. RESULTS: No statistically significant differences in BCVA were found between either IOL (0.06+/-0.06 and 0.05+/-0.07 logarithm of the minimum angle of resolution units for AcrySof SN60AT and AcrySof IQ groups, respectively; P = 0.091). One hundred percent of patients achieved BCVA of 20/32 or better in both groups. The percentage of patients who achieved BCVA of 20/25 or better was 86.3%. The AcrySof IQ IOL group showed better monocular and binocular CS at 6, 12, and 18 cpd under photopic conditions and at 3, 6, 12, and 18 cpd under mesopic conditions (P<0.001). CONCLUSIONS: Eyes implanted with the aspheric AcrySof IQ IOL showed better photopic and mesopic CS at medium and high spatial frequencies than eyes implanted with the spherical AcrySof SN60AT IOL. High-contrast photopic BCVA was similar between both IOLs. FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.
机译:目的:比较白内障手术后植入非球面和球面人工晶状体(IOL)的眼睛的视敏度和对比敏感度(CS)。设计:随机,前瞻性研究。参与者:来自262名白内障手术患者的254眼植入了2种IOL模型:AcrySof IQ(262眼)和AcrySof SN60AT(262眼;爱尔康实验室,德克萨斯州沃思堡)。方法:在高视力(85 cd / m(2))和中视(6 cd / m(2))条件下,测量高对比度视力最佳校正远视力(BCVA)和CS。在两种照明条件下,对瞳孔直径进行远距离视觉分析。所有患者均进行了6个月的随访。主要观察指标:在单眼和双眼条件下植入后,最佳矫正的远距离视敏度以及明视和中视CS。结果:两个IOL之间的BCVA均无统计学显着性差异(SN60AT和AcrySof IQ组的分辨率单位的最小分辨角分别为0.06 +/- 0.06和0.05 +/- 0.07; P = 0.091)。两组患者的BCVA均达到20/32或更高,达到100%。 BCVA达到20/25或更高的患者百分比为86.3%。 AcrySof IQ IOL组在明视条件下在6 cpd,12 cpd和18 cpd下在中视条件下表现出更好的单眼和双眼CS(P <0.001)。结论:与非球面AcrySof SN60AT IOL相比,植入非球面AcrySof IQ IOL的眼睛在中高空间频率下表现出更好的明视和中视CS。两种IOL之间的高对比度明视BCVA相似。财务披露:作者对本文讨论的任何材料均无所有权或商业利益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号