首页> 外文期刊>Ophthalmology >Hyperopia correction by noncontact holmium:YAG laser thermal keratoplasty. Clinical study with two-year follow-up.
【24h】

Hyperopia correction by noncontact holmium:YAG laser thermal keratoplasty. Clinical study with two-year follow-up.

机译:非接触contact:YAG激光热角膜移植术矫正远视。两年随访的临床研究。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Thermal keratoplasty to correct hyperopia has been attempted with nonlaser and laser devices. Problems have included long-term regression and irregular induced astigmatism. The present clinical study was performed to investigate the safety, efficacy, and stability of a noncontact mode of holmium: YAG laser energy delivery and a modified laser thermal keratoplasty treatment procedure for correction of low hyperopia. METHODS: Seventeen patients underwent noncontact holmium: YAG laser thermal keratoplasty in their nondominant eyes for correction of hyperopia of up to 3.00 diopters. Treatment parameters included simultaneous delivery of eight holmium: YAG laser spots in a symmetrical octagonal array with a centerline diameter of 6mm, 10 pulses of laser light at 5-Hz pulse repetition frequency, and pulse energies of 159 to 199mJ. Follow-up was 2 years in 15 of 17 patients. RESULTS: In the 15 eyes examined at 2 years after surgery, mean uncorrected distance Snellen visual acuity improved from 20/125-1 to 20/50-2. The mean change in spherical equivalent of subjective manifest refraction was -0.79 diopter. Eleven of these 15 eyes (73%) had a mean refractive correction of -1.1 diopters (range, -0.38 to -2.63 diopters); regression between 14 days and 2 years was 0.2 diopter. Four eyes (27%) had no persistent refractive correction (within +/- 0.25 diopter). Mean induced refractive astigmatism was 0.18 diopter. None of the eyes lost two or more lines of spectacle-corrected distance vision. The amount of refractive correction at 2 years after surgery was correlated to the treatment pulse energy and the volume of the opacified corneal tissue observed immediately after treatment. CONCLUSIONS: This technique of noncontact laser thermal keratoplasty produced safe, effective, and persistent corrections of low hyperopia in the majority of treated eyes.
机译:背景:已经尝试用非激光和激光设备进行热角膜移植术来矫正远视。问题包括长期消退和不规则诱发的散光。进行本临床研究以研究of的非接触模式的安全性,有效性和稳定性:YAG激光能量输送和改良的激光热角膜移植治疗程序,用于矫正弱视远视。方法:17例患者的非优势眼进行了非接触性:: YAG激光热角膜成形术,以矫正高达3.00屈光度的远视。处理参数包括以对称的八边形阵列同时传送八个:YAG激光点,对称的八边形阵列的中心线直径为6mm,以10 Hz的脉冲重复频率以5 Hz的脉冲重复频率发出,并且脉冲能量为159至199 mJ。 17例患者中有15例随访2年。结果:在手术后2年检查的15只眼睛中,Snellen的平均未矫正距离视力从20 / 125-1提高到20 / 50-2。主观表现屈光度的等效球面度平均变化为-0.79屈光度。这15只眼睛中有11只(73%)的平均屈光矫正为-1.1屈光度(范围-0.38至-2.63屈光度); 14天和2年之间的回归为0.2屈光度。四只眼睛(27%)没有持续屈光矫正(屈光度在+/- 0.25以内)。平均诱发屈光散光为0.18屈光度。没有人的眼睛失去两行或两行以上的眼镜矫正远视力。术后2年的屈光矫正量与治疗脉冲能量和治疗后立即观察到的不透明角膜组织的体积相关。结论:这种非接触式激光热角膜成形术技术可在大多数接受治疗的眼睛中安全,有效且持久地矫正弱视远视。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号