...
首页> 外文期刊>Ophthalmology >INTACS inserts for treating keratoconus: one-year results.
【24h】

INTACS inserts for treating keratoconus: one-year results.

机译:INTACS刀片用于治疗圆锥角膜:一年的结果。

获取原文
获取原文并翻译 | 示例

摘要

OBJECTIVE: To evaluate the use of INTACS micro-thin prescription inserts (Kera Vision, Inc., Fremont, CA) for the treatment of keratoconus. DESIGN: Prospective, nonrandomized (self-controlled) comparative trial. PARTICIPANTS/INTERVENTION: Ten patients from our prospective clinical study who had completed 12 months of follow-up were evaluated. All patients had keratoconus with clear central corneas and were contact lens intolerant. After reviewing corneal pachymetry and topography of individual patients, INTACS inserts of 0.45-mm thickness were placed in the inferior cornea to lift the cone and INTACS of 0.25-mm thickness were inserted superiorly to counterbalance and flatten the overall anterior corneal surface. MAIN OUTCOME MEASURES: Differences between preoperative and postoperative uncorrected visual acuity, best spectacle-corrected visual acuity, manifest refraction, and keratometry values were statistically assessed. Changes in corneal ectasia were evaluated by reviewing corneotopographic maps. RESULTS: No intraoperative complications occurred in this series of patients. Spherical equivalent error and refractive astigmatism were reduced with INTACS inserts treatment. Postoperative month 12 uncorrected visual acuity (logarithm of the minimum angle of resolution [logMAR] mean, 0.35, standard deviation [SD], 0.16 [approximately 20/50, approximately 2 lines]) was significantly better than preoperative (logMAR mean, 1.05; SD, 0.33 [approximately 20/200, approximately 3 lines]; P
机译:目的:评估INTACS超薄处方插入物(Kera Vision,Inc.,Fremont,CA)在圆锥角膜治疗中的应用。设计:前瞻性,非随机(自我控制)比较试验。参与者/干预措施:对来自我们前瞻性临床研究的10位完成了12个月随访的患者进行了评估。所有患者的圆锥角膜均具有清晰的中央角膜,并且不耐受角膜接触镜。在回顾了各个患者的角膜厚度和地形之后,将0.45毫米厚的INTACS插入物放置在下角膜以提起锥体,并向上插入0.25毫米厚的INTACS以平衡并平坦化整个前角膜表面。主要观察指标:对术前和术后未矫正视力,最佳眼镜矫正视力,明显屈光度和角膜曲率测定值之间的差异进行统计学评估。通过检查角膜地形图来评估角膜扩张的变化。结果:该系列患者均未发生术中并发症。使用INTACS刀片治疗可降低球面等效误差和屈光散光。术后12个月未矫正的视力(最小分辨角对数[logMAR]平均0.35,标准偏差[SD] 0.16 [大约20/50,大约2行]的对数)明显优于术前(logMAR平均1.05; SD,0.33 [约20/200,约3行]; P <或= 0.05)。与基线相比,术后第12个月的平均最佳眼镜矫正视力提高了约两行(logMAR均值,0.22; SD,0.12 [约20/32,约1线]; logMAR均值,0.38; SD,0.13 [约] 20/50,分别约为1行)。放置插入物后,所有受试者的角膜地形图形状(圆锥的大小和高度)均得到改善。结论:INTACS超薄处方插入物似乎为隐形眼镜不耐受的患者提供了治疗透明角膜圆锥角膜的可行方法。几乎所有眼睛的治疗都减少了与圆锥角膜相关的角膜变陡和散光,并且提高了视力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号