首页> 外文期刊>Ophthalmic surgery, lasers & imaging: the official journal of the International Society for Imaging in the Eye >Light scatter on the surface of AcrySof? intraocular lenses: Part I. Analysis of lenses retrieved from pseudophakic postmortem human eyes
【24h】

Light scatter on the surface of AcrySof? intraocular lenses: Part I. Analysis of lenses retrieved from pseudophakic postmortem human eyes

机译:光在AcrySof表面散射?人工晶状体:第一部分。从假晶状体验尸后人眼中取出的晶状体的分析

获取原文
获取原文并翻译 | 示例
           

摘要

■ BACKGROUND AND OBJECTIVE: To investigate the cause of light scatter measured on the surface of AcrySof intraocular lenses (Alcon Laboratories, Inc., Fort Worth, TX) retrieved from pseudophakic post-mortem human eyes. ■ MATERIALS AND METHODS: Ten intraocular lenses (Alcon AcrySof Model MA60BM) were retrieved postmortem and analyzed for light scatter before and after removal of surface-bound biofilms. ■ RESULTS: Six of the 10 lenses exhibited light scatter that was clearly above baseline levels. In these 6 lenses, both peak and average pixel density were reduced by approximately 80% after surface cleaning. ■ CONCLUSION: The current study demonstrates that a coating deposited in vivo on the lens surface is responsible for the light scatter observed when incident light is applied.
机译:■背景与目的:研究从假晶状验尸后的人眼中获得的人工晶状体(Alcon Laboratories,Inc.,Fort Worth,TX)上的AcryS人工晶状体表面测量的光散射的原因。 ■材料和方法:取死后取回10颗人工晶状体(Alcon AcrySof MA60BM型),并分析去除表面结合的生物膜前后的光散射。结果:10个镜片中有6个的光散射明显高于基线水平。在这6个镜头中,表面清洁后,峰值和平均像素密度均降低了约80%。结论:目前的研究表明,在体内沉积在镜片表面的涂层是在施加入射光时观察到的光散射的原因。