Biomechanical and Morphological Differences between the Sclera Canal Ring and a Peripheral Sclera Ring in the Porcine Eye.

机译:猪眼巩膜管环和周围巩膜环之间的生物力学和形态学差异。

获取原文
获取原文并翻译 | 示例
           

摘要

Aim: To investigate a possible association between the biomechanical load and unload behaviour and the elastin content of the sclera canal ring (SCR) and a superiorly localized sclera ring (SPS) in the porcine eye. Methods: Two sclera rings were trephined from each of 40 porcine eyes, one containing the SCR and the other an SPS. The load and the unload curves were measured in the extension range of 0-2.0 mm by a biomaterial tester. Hysteresis was determined from the area enclosed by the loading and unloading curve. Histochemical staining with resorcin-fuchsin and morphometric analysis of paraffin-embedded sections of both rings were performed to detect the area occupied by elastin fibres. Results: At 1 mm extension, the mean load of the SCR was 0.89 +/- 0.22 N and that of the SPS 1.13 +/- 0.19 N, which was not significantly different between both rings (p > 0.05). Mean hysteresis in the SCR was 1.55 +/- 0.30 N x mm and 1.90 +/- 0.18 N x mm in the SPS, which was significantly different between both rings (p = 0.01). Mean sclera thickness was 986 mum in the SCR (range: 900-1,060 mum) and 971 mum in the SPS (range: 800-1,200 mum) without a statistically significant difference between both sclera rings (p = 0.78). The area occupied by elastin fibres was 15.5 +/- 3.4% in the SCR and 4.5 +/- 1.5% in the SPS, which was significantly different between both rings (p = 0.0001). Conclusion: Hysteresis in the SCR was significantly lower than in the SPS, indicating a higher elasticity of the SCR in the porcine eye. This effect could be explained by a higher content of elastin in the surrounding ring of the peripapillary optic nerve head providing reversible contraction in cases of intra-ocular pressure variations.
机译:目的:研究猪眼中生物力学负载和卸载行为与巩膜管环(SCR)和局部局限性巩膜环(SPS)的弹性蛋白含量之间的可能联系。方法:从40只猪眼中分别摘除2个巩膜环,其中一只包含SCR,另一只包含SPS。用生物材料测试仪在0-2.0mm的延伸范围内测量载荷和卸载曲线。从加载和卸载曲线所包围的区域确定磁滞。用间苯二酚-品红进行组织化学染色,并对两个环的石蜡包埋部分进行形态分析,以检测弹性蛋白纤维所占的面积。结果:在延伸1 mm时,SCR的平均载荷为0.89 +/- 0.22 N,SPS的平均载荷为1.13 +/- 0.19 N,两个环之间无显着差异(p> 0.05)。 SCR中的平均磁滞为1.55 +/- 0.30 N x mm,而SPS中的平均磁滞为1.90 +/- 0.18 N x mm,两个环之间存在显着差异(p = 0.01)。 SCR的平均巩膜厚度为986微米(范围:900-1,060微米),SPS的平均巩膜厚度为971微米(范围:800-1,200微米),两个巩膜环之间的差异均无统计学意义(p = 0.78)。弹性蛋白纤维在SCR中占15.5 +/- 3.4%,在SPS中占4.5 +/- 1.5%,两个环之间存在显着差异(p = 0.0001)。结论:SCR中的磁滞明显低于SPS中的磁滞,这表明SCR在猪眼中的弹性较高。眼内压变化的情况下,在乳头周围视神经头周围环中弹性蛋白含量较高,可逆收缩,可以解释这种效果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号