Purpose: To evaluate the usefulness of a virtual ultrasound (US) imaging device as a tool to assist novice sonographers. Materials and Methods: A prospective blinded pilot study was conducted involving patients with liver lesions. Two sonographers and 2 medical doctors with less than 5 years of experience performed US examinations. The time needed to detect liver lesions on US and the success rate for detecting liver lesions with and without using the virtual US imaging device SYNAPSE VINCENT (R) (Fujifilm Medical Co., Tokyo, Japan) before US examination were evaluated. Results: Thirty-two patients with the following 42 liver lesions were included: liver cyst (n = 24), hemangioma (n = 8), hepatocellular carcinoma (n = 6), and liver metastasis (n = 4). The maximal diameter of these lesions ranged from 0.3 to 1.5 cm (mean +/- SD, 0.8 +/- 0.4). The average time for detecting liver lesions on US was 47.8 s (range, 7-113) with VINCENT and 112.9 s (range, 14-313) without VINCENT before US examination. There were significant differences in the duration of US examination with and without VINCENT (p = 0.0002, Student's t test). The rates for accurately detecting liver lesions were 100 and 76.2% (16/21) in US beginners with and without VINCENT, respectively. Significantly higher detection rates were found in the US beginners who used VINCENT compared to those who did not use VINCENT (p = 0.047, Fisher's exact test). Conclusion: Before US examination, a reference with VINCENT could contribute to the successful detection of liver lesions and could be time-saving for US beginners. (C) 2014 S. Karger AG, Basel
机译:目的:评估虚拟超声(US)成像设备作为辅助新手超声医师的工具的有效性。材料和方法:一项涉及肝病患者的前瞻性盲实验研究。两名经验不足5年的超声检查师和2位医生进行了美国检查。在美国检查之前,评估了在美国检查肝脏病变所需的时间以及在使用和不使用虚拟美国成像设备SYNAPSE VINCENT(R)(富士胶片医疗公司,东京,日本)时检测肝脏病变的成功率。结果:包括以下42例肝脏病变的32例患者:肝囊肿(n = 24),血管瘤(n = 8),肝细胞癌(n = 6)和肝转移(n = 4)。这些病变的最大直径为0.3到1.5厘米(平均+/- SD,0.8 +/- 0.4)。在进行USCENT检查之前,在USVIN上发现肝脏病变的平均时间为47.8 s(范围为7-113),而在没有VINCENT的情况下,平均时间为112.9 s(范围为14-313)。在有和没有VINCENT的情况下,美国考试的持续时间存在显着差异(p = 0.0002,Student's t检验)。在有VINCENT和无VINCENT的美国初学者中,准确检测肝脏病变的发生率分别为100%和76.2%(16/21)。与不使用VINCENT的美国初学者相比,在使用VINCENT的美国初学者中发现的检出率显着更高(p = 0.047,Fisher精确检验)。结论:在进行US检查之前,使用VINCENT进行参考可能有助于成功地检测出肝脏病变,并可能为美国初学者节省时间。 (C)2014 S.Karger AG,巴塞尔

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号