Worldwide, many people suffer from osteoarthritis, a painful condition that interferes with normal work and the enjoyment of life and is thus a serious personal and public problem. Good management of osteoarthritis requires methodologies for accurate and timely detection of disease onset, progression and response to treatment. Here, capacitive electrochemical immunosensors, using immobilized antibodies against the known osteoarthritis biomarker human cartilage chitinase-3-like protein 2, also known as hYKL-39, were used as novel tools for sensitive and selective osteoarthritis analysis. In the proposed procedure the current response of the sensor to a potential step application is measured; from the resultant traces, concentration-dependent capacitance changes, due to antigen binding, can be calculated. The linear range and detection limit of capacitive hYKL-39 immunosensing were respectively 0.1-1000 mu g L-1 and 0.074 mu g L-1. This was better than the characteristics of the enzyme-linked immunosorbent assay (ELISA) with an optical readout, which is presently the standard practice for laboratory hYKL-39 screening. In synovial fluid samples from osteoarthritis patients, capacitive hYKL-39 immunosensing reported the expected elevated hYKL-39 biomarker levels in quantitative agreement with ELISA analysis. The improved detection limit and linear range of the electrochemical hYKL-39 immunoassay combined with the potential of cheap, simple, miniaturizable, portable and automatable equipment recommend this novel approach as a promising complementary tool and ideal reference assay for osteoarthritis diagnosis and monitoring, in particular when the aim is early detection.
机译:在世界范围内,许多人患有骨关节炎,这是一种痛苦的疾病,会干扰正常的工作和生活,因此是一个严重的个人和公共问题。良好地管理骨关节炎需要准确,及时地检测疾病发作,进展和对治疗的反应的方法。在这里,电容性电化学免疫传感器使用针对已知的骨关节炎生物标志物人类软骨几丁质酶-3样蛋白2(也称为hYKL-39)的固定化抗体,用作敏感和选择性骨关节炎分析的新型工具。在建议的过程中,测量传感器对潜在步进应用的电流响应;从产生的痕迹,可以计算出由于抗原结合而产生的浓度依赖性电容变化。电容性hYKL-39免疫传感的线性范围和检测极限分别为0.1-1000μgL-1和0.074μgL-1。这优于具有光学读数的酶联免疫吸附测定(ELISA)的特性,该特性目前是实验室hYKL-39筛选的标准操作。在骨关节炎患者的滑液样本中,电容性hYKL-39免疫感应报告了与ELISA分析定量一致的预期的hYKL-39生物标志物水平升高。电化学hYKL-39免疫测定法的改进的检测限和线性范围,再加上廉价,简单,可小型化,便携式和自动化设备的潜力,特别推荐这种新颖方法作为骨关节炎诊断和监测的有希望的补充工具和理想的参考测定法目的是及早发现。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号