A novel device for the measurement of proprioception in the hand.

机译:一种用于测量手中的本体感受的新颖装置。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Together with visual information, awareness of limb position and movement is essential for limb coordination. A proprioceptive deficit has been demonstrated in a number of rheumatological disorders. There is a lack of a portable device for measuring hand proprioception in the field. METHODS: A compact portable device for measuring joint position sense in the metacarpophalangeal joint of the index finger of either hand was constructed. This device was manually operated and required the subject to match the position of the hidden finger with a surface-mounted silhouette. Reliability studies were performed over three consecutive days in 12 normal volunteers. RESULTS: Intrasubject variability [95% confidence interval (CI)] was 0.86 degrees (0.04-1.76) between days 1 and 2, and 1.23 degrees (1.04-3.50) between days 2 and 3. The intraclass correlation coefficient (95% CI) between all 3 days was 0.92 (0.85-0.96). Average proprioceptive error (95% CI) in the sample population was 5.72 degrees (1.23-10.2) over the 3 days. This value was 5.94 degrees , 5.79 degrees and 5.42 degrees on days 1, 2 and 3, respectively. No difference was found between sexes but dominant hands gave smaller errors (mean dominant error 5.11 degrees , mean non-dominant error 6.35 degrees ; t = -3.4, P = 0.002). CONCLUSIONS: This report describes a new portable device for measuring proprioception in the hand. Reproducibility was shown to be good on an individual and group basis. These results are promising and warrant larger age- and sex-related studies. The ease and portability of the device make it ideal for use in epidemiological studies of rheumatological disorders involving the hands, including joint hypermobility.
机译:背景:与视觉信息一起,对肢体位置和运动的意识对于肢体协调至关重要。在许多风湿病中已证明了本体感受缺陷。在该领域中缺少用于测量手本体感觉的便携式设备。方法:构建了一种紧凑的便携式设备,用于测量两只手的食指的掌指关节中的关节位置感。该设备是手动操作的,要求受试者将隐藏手指的位置与表面安装的轮廓相匹配。连续三天对12名正常志愿者进行了可靠性研究。结果:受试者内部变异[95%置信区间(CI)]在第1天和第2天之间为0.86度(0.04-1.76),在第2天和第3天之间为1.23度(1.04-3.50)。组内相关系数(95%CI)所有3天之间的差值为0.92(0.85-0.96)。在三天内,样本人群的平均本体感受误差(95%CI)为5.72度(1.23-10.2)。该值在第1、2和3天分别为5.94度,5.79度和5.42度。性别之间没有差异,但优势手的误差较小(平均优势误差5.11度,平均非优势误差6.35度; t = -3.4,P = 0.002)。结论:本报告介绍了一种用于测量手中本体感觉的新型便携式设备。在个人和团体的基础上,重现性都很好。这些结果是有希望的,并有必要进行与年龄和性别有关的更大的研究。该设备的易用性和便携性使其非常适合用于涉及手(包括关节过度活动)的风湿病的流行病学研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号