Throughout the world, steel is melted in high-power electrical arc furnaces. Such furnaces, fed by either direct or alternating current, have power ratings of more than 100 MW. The operation of AC electrical arc furnaces causes system perturbations in the supplying network due to unbalanced fluctuations of active and reactive power in the three-phase system lines and due to the non-linear V-A-characteristic of the electrical high-current arc. Consequently, the decrease in power quality may interfere with power grid operation. In the majority of cases, inadmissible distortions, unbalances and highly dynamic fluctuations of system voltage must be avoided by using compensators. Requirements for such compensators are: Supply of reactive power (base load) for limitation of voltage deviations. Filtering to keep voltage distortions within permissible limits. Controlled supply of unbalanced reactive power for mitigation of impermissible voltage fluctuations in association with flicker and time varying unbalances.
机译:全世界,钢都是在大功率电弧炉中熔化的。这种由直流电或交流电供电的熔炉的额定功率超过100 MW。交流电弧炉的运行会由于三相系统线路中有功和无功功率的不平衡波动以及大电流电弧的非线性V-A特性而在供电网络中引起系统扰动。因此,电能质量的下降可能会干扰电网的运行。在大多数情况下,必须通过使用补偿器来避免不允许的失真,不平衡和系统电压的高度动态波动。此类补偿器的要求是:提供无功功率(基本负载)以限制电压偏差。滤波以使电压失真保持在允许的范围内。控制不平衡无功功率的供应,以减轻与闪烁和时变不平衡相关的不允许的电压波动。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号