首页> 外文期刊>Resuscitation. >Effects of an inspiratory impedance threshold device on blood pressure and short term survival in spontaneously breathing hypovolemic pigs.
【24h】

Effects of an inspiratory impedance threshold device on blood pressure and short term survival in spontaneously breathing hypovolemic pigs.

机译:吸气阻抗阈值设备对自发呼吸性低血容量猪的血压和短期存活的影响。

获取原文
获取原文并翻译 | 示例
       

摘要

BACKGROUND: The inspiratory impedance threshold device (ITD) has been shown to improve hemodynamic variables and survival outcomes during cardiopulmonary resuscitation in animals and humans. We hypothesized that use of an ITD, with a resistance of -10 cm H2O, will improve hemodynamics and short-term survival rates during hypovolemic hypotension in spontaneously breathing pigs. METHODS: Female farm pigs ( approximately 26 kg) were intubated and anesthetized with propofol with the dose adjusted to permit spontaneous respirations. They were bled to 50% of calculated blood volume through an arterial catheter and then prospectively randomized to either treatment with an ITD or observation alone. Arterial and intratracheal pressures as well as arterial blood gases were measured. After 90 min the ITD was removed, normal saline was administered to all surviving animals, the anesthetic was discontinued, and animals were allowed to recover. Statistical analysis was performed with one-way repeated ANOVA and survival rates were calculated with Kaplan-Meier analysis. RESULTS: Treatment with the ITD resulted in lower intratracheal inspiratory pressure in the treatment group (-11+/-0.4 mmHg versus -4+/-0.7 mmHg, respectively, P<0.005). Mean arterial pressure after 30 min of treatment with the ITD was higher in the treatment group (61.1+/-5.5 mmHg versus 37.4+/-2.1 mmHg, respectively, P<0.005). All pigs in the control group died within 65 min of the initial bleed, whereas 7/8 (87%) treated with an ITD survived for >90 min (P<0.001). During the recovery phase, 6/8 (75%) in the ITD group survived for >3h and awoke without neurological deficit; one surviving animal in the ITD group never woke up. Arterial oxygenation was not compromised in the ITD group. CONCLUSIONS: Use of an ITD improved blood pressure and short-term survival rates in a spontaneously breathing porcine model of hypovolemic hypotension.
机译:背景:吸入阻抗阈值设备(ITD)已被证明可以改善动物和人类心肺复苏过程中的血流动力学变量和生存结果。我们假设使用具有-10 cm H2O阻力的ITD在自发呼吸的猪低血容量性低血压期间将改善血流动力学和短期存活率。方法:将雌性猪(约26公斤)插管并用异丙酚麻醉,并调整剂量以允许自发呼吸。通过动脉导管将其放血至计算出的血液量的50%,然后前瞻性地随机分为ITD治疗组或单独观察。测量动脉和气管内压力以及动脉血气。 90分钟后,取出ITD,向所有存活的动物注射生理盐水,停止麻醉,让动物恢复健康。使用单向重复方差分析进行统计分析,并通过Kaplan-Meier分析计算生存率。结果:ITD治疗导致治疗组气管内吸气压力降低(分别为-11 +/- 0.4 mmHg和-4 +/- 0.7 mmHg,P <0.005)。 ITD治疗30分钟后的平均动脉压在治疗组较高(分别为61.1 +/- 5.5 mmHg和37.4 +/- 2.1 mmHg,P <0.005)。对照组中的所有猪均在初次出血后65分钟内死亡,而用ITD处理的7/8(87%)存活时间大于90分钟(P <0.001)。在恢复阶段,ITD组中有6/8(75%)存活了3小时以上,并且没有神经功能障碍而苏醒。 ITD小组中的一只幸存动物从未醒来。 ITD组的动脉氧合没有受到损害。结论:在自发性低血容量性低血压猪模型中,ITD的使用可改善血压和短期生存率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号