Yellow fever is a disease caused by the prototype virus of the genus Flavivirus and remains endemic in tropical forest regions from Africa and South America, despite the availability of effective vaccines. These are capable of inducing a rapid specific immune response, with the formation of neutralizing antibodies that appear early, are protective and long lasting. The Plaque Reduction Neutralization Test is considered the most sensitive and specific test for quantification of neutralizing antibodies, and the reference method for assessing the protective immune response after vaccination. This study evaluated the reliability (repeatability and reproducibility) and accuracy (sensitivity, specificity and overall accuracy) of micro-PRNT50 and compared its performance with the micro-PRNT90. Although the micro-PRNT50 has showed satisfactory levels of reliability (ICCs ranged from 0.62 to 0.NorNormas e Manuais Técnicosas e Manuais Técnicos6 for repeatability and 0.72 for reproducibility) and accuracy (sensitivity of 91.1%, specificity of 72.9% and overall accuracy of 78%), the micro-PRNT90 showed higher performance, with ICCs for repeatability ranged from 0.78 to 0.79 and 0.81 for reproducibility, sensitivity of 100%, specificity of 94.7% and overall accuracy of 95%. Modifications in the test methodology and changes in the classification criteria in the readings of the results obtained will be important to improve the accuracy of micro-PRNT.
机译:黄热病是由黄病毒属病毒原型病毒引起的疾病,尽管有有效的疫苗,但在非洲和南美的热带森林地区仍是地方性流行病。它们能够诱导快速的特异性免疫反应,并形成早期出现的中和抗体,具有保护性和持久性。斑块减少中和试验被认为是定量中和抗体的最灵敏和最特异性的试验,也是评估接种疫苗后保护性免疫应答的参考方法。这项研究评估了微型PRNT50的可靠性(可重复性和再现性)和准确性(灵敏性,特异性和整体准确性),并将其性能与微型PRNT90进行了比较。尽管micro-PRNT50的可靠性水平令人满意(ICC范围为0.62至0。 %),micro-PRNT90表现出更高的性能,ICC的重现性在0.78至0.79之间,重现性在0.81之间,灵敏度为100%,特异性为94.7%,整体准确性为95%。测试方法的修改和所得结果读数的分类标准的更改对于提高微型PRNT的准确性非常重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号