Effect of high-energy Li-7(2+) ions on the TL behavior of LiF : Mg,Cu,P detectors

机译:Li-7(2+)高能离子对LiF的TL行为的影响:Mg,Cu,P检测器

获取原文
获取原文并翻译 | 示例

摘要

Thermoluminescence (TL) of LiF:Mg,Cu,P (TLD-700H) phosphor irradiated with 24 MeV Li-7 ions at different fluences in the range 5 x 10(9)-1 x 1012 ions/cm(2) (with corresponding doses in the range 620Gy to 123.96kGy) has been studied. The samples from the same batch were also exposed to gamma-rays from a Co-60 source for comparative studies. It has been found that at low fluences (5 x 10(9)-1 x 10(10) ions/cm(2)) the TL glow curves of the samples irradiated with Li-7 ions have similar structures to that of gamma-irradiated sample, while at higher fluences (5 x 10(10)-1 x 1012 ions/cm(2)) the relative intensities and fluence responses of the TL glow peaks were observed to vary with fluences increasing. The TL intensity of the dosimetric peak at 481 K saturates at the fluence 5 x 10(11) ions/cm(2), while that of the peak at 524 K increases till the maximum fluence 1 x 10(12) ions/cm(2), All the TL glow peaks show nearly sublinear behavior except the peak at 524 K, which exhibits supralinear. This has been attributed to the formation of more defects (trapping centers (TC)/luminescence centers (LC)) due to Li-7 ions implantation. during ion beam irradiation. The implantation has been confirmed from TRIM calculations. Moreover, on ion beam irradiation, a shift in the peak positions toward lower temperature side by around 10K was observed, comparing with those induced by Co-60 gamma-rays. The TL efficiency of LiF:Mg,Cu,P to 24 MeV 7Li ion beam has been measured relative to gamma-rays of Co-60. Further, theoretical analysis of the glow curves of the ion beam and gamma-irradiated samples was done by glow curve deconvolution (GCD) method to determine trapping parameters of various peaks. As LiF:Mg,Cu,P is highly sensitive and tissue equivalent TLD material and its peak at 524 K does not saturate even at high fluences. this peak may be used for the dosimetry of ion beams in medical and other applications. (c) 2007 Elsevier Ltd. All rights reserved.
机译:LiF:Mg,Cu,P(TLD-700H)荧光粉的热发光(TL)以不同的通量在5 x 10(9)-1 x 1012离子/ cm(2)范围内辐照24 MeV Li-7离子已经研究了在620Gy至123.96kGy范围内的相应剂量。来自同一批次的样品也暴露于来自Co-60来源的伽马射线,以进行比较研究。已经发现,在低通量(5 x 10(9)-1 x 10(10)离子/ cm(2))时,用Li-7离子辐照的样品的TL辉光曲线具有与γ-射线相似的结构。辐照的样品,虽然通量更高(5 x 10(10)-1 x 1012离子/ cm(2)),但TL辉光峰的相对强度和通量响应随通量的增加而变化。在481 K处的剂量峰的TL强度在通量5 x 10(11)离子/ cm(2)时达到饱和,而在524 K处的峰的TL强度增加直到最大通量1 x 10(12)离子/ cm( 2),除524 K处的超线性峰外,所有TL辉光峰均表现出几乎亚线性的行为。这归因于由于Li-7离子注入而形成的更多缺陷(陷阱中心(TC)/发光中心(LC))。在离子束照射期间。植入已通过TRIM计算得到证实。另外,在离子束照射下,与由Co-60伽马射线引起的峰位置相比,观察到峰位置向低温侧移动了约10K。 LiF:Mg,Cu,P对24 MeV 7Li离子束的TL效率已相对于Co-60的伽马射线进行了测量。此外,通过辉光曲线反褶积(GCD)方法对离子束和伽马射线辐照样品的辉光曲线进行了理论分析,以确定各种峰的捕获参数。由于LiF:Mg,Cu,P是高度敏感的组织等效TLD材料,即使在高通量下,其在524 K处的峰也不会饱和。该峰可用于医疗和其他应用中的离子束剂量测定。 (c)2007 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号