首页> 外文期刊>Radiation measurements >Reconstruction of doses absorbed by radiotherapy patients by means of EPR dosimetry in tooth enamel
【24h】

Reconstruction of doses absorbed by radiotherapy patients by means of EPR dosimetry in tooth enamel

机译:通过牙釉质中EPR剂量测定法重建放疗患者吸收的剂量

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

The objective of this study was verification of actual doses absorbed by teeth enamel in patients undergoing radiotherapy treatment. The retrospective dosimetry was based on ex vivo measurements of electron paramagnetic resonance (EPR) signals in teeth extracted from six patients during dental treatment within a few years after radiotherapy with Co-60 photons and high-energy photon and electron beams. The measured doses were compared to those calculated by radiotherapy treatment planning (RTP) algorithm (CadPlan 3.1). The total accuracy of dose reconstructions based on EPR measurements was 5-9%. The discrepancy between the planned and measured doses ranged from a few percent (for teeth positioned within the irradiated field) up to about 120% (for teeth located outside the primary beam). Such significant differences between results of RTP calculations and EPR measurement can be explained by changes in geometry of tissues within patient's oral cavity during the treatment, which cannot be accounted for by RTP based on radiotherapy simulation procedure preceding the treatment. (c) 2007 Elsevier Ltd. All rights reserved.
机译:这项研究的目的是验证接受放射治疗的患者牙釉质吸收的实际剂量。回顾性剂量测定法是基于对60名Co-60光子以及高能光子和电子束进行放射治疗后几年内在牙科治疗过程中从六名患者中提取的牙齿中离体电子顺磁共振(EPR)信号的离体测量结果。将测得的剂量与通过放射治疗治疗计划(RTP)算法(CadPlan 3.1)计算出的剂量进行比较。基于EPR测量的剂量重建的总准确度为5-9%。计划剂量与测量剂量之间的差异范围从百分之几(对于位于照射野内的牙齿)到大约120%(对于位于主光束之外的牙齿)。 RTP计算结果与EPR测量结果之间的显着差异可以通过治疗过程中患者口腔内组织几何形状的变化来解释,RTP无法根据治疗前的放射疗法模拟程序来解释这一点。 (c)2007 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号