首页> 外文期刊>Radiation measurements >The response of a spherical tissue-equivalent proportional counter to different heavy ions having similar velocities
【24h】

The response of a spherical tissue-equivalent proportional counter to different heavy ions having similar velocities

机译:球形组织等效比例计数器对具有相似速度的不同重离子的响应

获取原文
获取原文并翻译 | 示例
           

摘要

A tissue-equivalent proportional counter (TEPC) has been used as a dosimeter in mixed radiation fields. Since it does not measure LET directly, the response function must be characterized in order to estimate quality factor and thus equivalent dose for the incident radiation. The objectives of this study were to measure the response of a spherical TEPC for different high-energy heavy ions (HZE) having similar velocity and to determine how quality factors can be determined. Data were obtained at the HIMAC heavy ion accelerator for He-4 and C-12 at 220 +/- 5 MeVucleon (beta = 0.59) and C-12, O-16, Si-28 and Fe-56 at 376 +/- 15 MeVucleon (beta = 0.70). A particle spectrometer recorded the charge and position of each incident beam particle. Events with low energy deposition were observed for particles that passed through the wall of the TEPC but not through the sensitive volume. The frequency averaged lineal energy, (y) over bar (f) was always less than the LET of the incident particles. The dose averaged lineal energy, D, was approximately equal to LET for particles with LET greater than 10keV/mu m, whereas D was larger than LET for the lighter particles with lower LET. Part of this effect is due to detector resolution and energy straggling that increases the variance of the response function. Although the TEPC is not a LET spectrometer, it can provide real time measurements of dose and provide estimates of quality factors for HZE particles using averaged values of lineal energy. (c) 2006 Published by Elsevier Ltd.
机译:组织等效比例计数器(TEPC)已用作混合辐射场中的剂量计。由于它不能直接测量LET,因此必须对响应函数进行表征,以便估算品质因数,从而估算入射辐射的等效剂量。这项研究的目的是测量球形TEPC对具有相似速度的不同高能重离子(HZE)的响应,并确定如何确定品质因数。数据是在HIMAC重离子加速器上获得的He-4和C-12的220 +/- 5 MeV /核子(β= 0.59)以及C-12,O-16,Si-28和Fe-56的376 + 15 MeV /核子(β= 0.70)。粒子光谱仪记录每个入射光束粒子的电荷和位置。对于通过TEPC壁但未通过敏感体积的粒子,观察到低能量沉积的事件。横条(f)上的平均频率线性能量(y)始终小于入射粒子的LET。对于LET大于10keV /μm的颗粒,剂量平均线性能量D大约等于LET,而对于LET较低的较轻颗粒,D大于LET。这种影响的部分原因是由于检测器的分辨率和能量散乱增加了响应函数的方差。尽管TEPC不是LET光谱仪,但它可以使用线能量的平均值来提供剂量的实时测量并提供HZE粒子的品质因数估计。 (c)2006年由Elsevier Ltd.发布。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号