首页> 外文期刊>Radiation Research: Official Organ of the Radiation Research Society >The response of tissue-equivalent proportional counters to heavy ions
【24h】

The response of tissue-equivalent proportional counters to heavy ions

机译:组织等效比例计数器对重离子的响应

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The paper presents a theoretical model for the response of a tissue-equivalent proportional counter (TEPC) irradiated with charged particles. Heavy ions and iron ions in particular constitute a significant part of radiation in space. TEPCs are used for all space shuttle and International Space Station (ISS) missions to estimate the dose and radiation quality (in terms of lineal energy) inside spacecraft. The response of the tissue-equivalent proportional counters shows distortions at the wall/cavity interface. In this paper, we present microdosimetric investigation using Monte Carlo track structure calculations to simulate the response of a TEPC to charged particles of various LET (1 MeV protons, 2.4 MeV alpha particles, 46 MeVueleon Ne-20, 55 MeVucleon Ne-20, 45 MeVucleon Ar-40, and 1.05 GeVucleon Fe-56). Data are presented for energy lost and energy absorbed in the counter cavity and wall. The model calculations are in good agreement with the results of Rademacher et al (Radiat. Res. 149, 387-389, 1998), including the study of the interface between the wall and the sensitive region of the counter. It is shown that the anomalous response observed at large event sizes in the experiment is due to an enhanced entry of secondary electrons from the wall into the gas cavity. (C) 2002 by Radiation Research Society. [References: 24]
机译:本文提出了一种理论模型,用于对带电粒子辐照的组织当量比例计数器(TEPC)进行响应。特别是重离子和铁离子构成了空间辐射的重要组成部分。 TEPC用于所有航天飞机和国际空间站(ISS)任务,以估算航天器内部的剂量和辐射质量(以线能量而言)。组织等效比例计数器的响应显示壁/腔界面处的变形。在本文中,我们介绍了使用蒙特卡洛轨道结构计算进行的微剂量研究,以模拟TEPC对各种LET(1 MeV质子,2.4 MeVα粒子,46 MeV /核Ne-20、55 MeV /核子Ne)的带电粒子的响应-20、45 MeV /核子Ar-40和1.05 GeV /核子Fe-56)。呈现了在相对腔和壁中损失的能量和吸收的能量的数据。模型计算与Rademacher等人的结果(Radiat。Res。149,387-389,1998)非常吻合,包括研究壁与柜台敏感区域之间的界面。结果表明,在大型事件中观察到的异常响应是由于二次电子从壁进入气腔的增强。 (C)2002年,辐射研究学会。 [参考:24]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号