摘要

In general sorption coefficients, K-d cat ion exchange capacity, CEC, and BET surface areas are measured on crushed rock samples because it is very time consuming to measure K-d and CEC on larger rock pieces as it takes a long time for the sorbing species to penetrate into and equilibrate a large sample. Also conventional sample holders for BET measurements are too small to hold a large sample. We have manufactured large sample holders for BET measurements and modified the equipment so that it is possible to measure BET surface areas on samples with 50 mm diameter and LIP to 100 mm length. Results are presented for intact pieces and compared to results on crushed material from the same drillcore. For K-d and CEC measurements we have developed a technique and equipment by which ions can be made to rapidly intrude into and equilibrate the internal surfaces of the same size samples as mentioned above. The method is based on electro-migration where the sample is placed between two vessels one with an anode and other with a cathode. The electric potential gradient drives the ions into and through the sample very much faster than molecular diffusion does. With Cs as the sorbing ion a few weeks were sufficient to equilibrate the 50 mm long sample. In previous diffusion experiments it took more than a year to equilibrate a 15 mm thick sample. A special mixing technique eliminates the development of low and high PH in the electrode compartments. K-d results from measurements on an intact drillcore are presented and comparison is made with results obtained on crushed material from the same bore core. The results from the sorption experiments are compared with the results from the BET surface area determinations in an attempt to evaluate the use of the BET surface area as a proxy for sorption behaviour.
机译:在一般的吸附系数中,在破碎的岩石样品上测量Kd阳离子交换容量,CEC和BET表面积,因为在较大的岩石块上测量Kd和CEC非常耗时,因为吸附物质渗透需要很长时间并平衡一个大样本。同样,用于BET测量的常规样品架太小而无法容纳大样品。我们已经制造了用于BET测量的大型样品架,并对设备进行了改进,从而可以测量直径50 mm,长度为100 mm的LIP样品的BET表面积。给出了完整碎片的结果,并与来自同一钻芯的压碎材料的结果进行了比较。对于K-d和CEC测量,我们开发了一种技术和设备,通过该技术和设备,可以使离子快速进入并平衡上述相同大小样品的内表面。该方法基于电迁移,其中将样品放置在两个带有阳极的容器之间,另一个带有阴极。电势梯度使离子进入和通过样品的速度比分子扩散快得多。用Cs作为吸附离子,几周就足以平衡50 mm长的样品。在以前的扩散实验中,平衡15毫米厚的样品用了一年多的时间。特殊的混合技术消除了电极室中PH偏高的问题。给出了在完整钻芯上的测量结果的K-d结果,并与从相同孔芯的压碎材料获得的结果进行了比较。将吸附实验的结果与BET表面积测定的结果进行比较,以尝试评估BET表面积作为吸附行为的代表。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号