Naturally occurring radon ~(222)Rn in indoor air is a significant cause of lung cancer and the houses are an important exposure location due to the large proportion of time spent at home. The indoor radon measurements have been carried out in some of the dwellings belonging to different villages of Fatehbad and Hisar districts of Western Haryana. LR-115 Type II plastic track detectors in bare mode were used for the measurement of indoor radon concentration for over a period of one year. The calculated annual average indoor radon concentration values vary from 126.3 Bq m~(-3) to 172.1 Bq m~(-3) with an average value of 145.21 Bq m~(-3), which is less than the recommended action level (200-300 Bq m~(-3)). The values of annual effective dose vary from 2.16 mSv to 2.94 mSv which is less than the lower limit of the recommended action level (3-10 mSv). The measured values of lifetime fatality risk vary from 1.67 to 2.27 with an average value of 1.92. The winter to summer ratio calculated for the studied dwellings ranges from 0.86 to 2.15 with an average of 1.46. The results indicate that the indoor radon concentration is higher in winter season than in the summer season. An attempt has also been made to find a correlation between the ventilation conditions and the measured values of indoor radon concentration. In most of the cases the radon values are less in well ventilated houses than partially/poorly ventilated houses. The measured indoor radon concentration values for the studied area are on the higher side than the world average of 40 Bq m~(-3).
机译:室内空气中天然存在的ra〜(222)Rn是导致肺癌的重要原因,由于在家中花费的时间比例很高,房屋是重要的暴露地点。室内ra测量是在哈里亚纳邦西部法塔赫巴德和希萨尔地区不同村庄的一些住宅中进行的。裸露模式下的LR-115 II型塑料径迹检测器用于测量室内ra浓度一年以上。计算出的室内年平均ra浓度值从126.3 Bq m〜(-3)到172.1 Bq m〜(-3)不等,平均值为145.21 Bq m〜(-3),小于建议的操作水平( 200-300 Bq m〜(-3))。年度有效剂量值从2.16 mSv到2.94 mSv不等,小于建议的操作水平的下限(3-10 mSv)。终生死亡风险的测量值从1.67到2.27不等,平均值为1.92。计算得出的住宅的冬夏比率为0.86至2.15,平均为1.46。结果表明,冬季室内than浓度高于夏季。还试图找到通风条件与室内ra浓度的测量值之间的相关性。在大多数情况下,通风良好的房屋中的ra值要低于部分通风不良的房屋中的ra值。研究区域测得的室内ra浓度值高于世界平均水平40 Bq m〜(-3)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号