首页> 外文期刊>Radiation and Environmental Biophysics >In vitro RABiT measurement of dose rate effects on radiation induction of micronuclei in human peripheral blood lymphocytes
【24h】

In vitro RABiT measurement of dose rate effects on radiation induction of micronuclei in human peripheral blood lymphocytes

机译:体外RABiT测量剂量率对人外周血淋巴细胞微核辐射诱导的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Developing new methods for radiation biodosimetry has been identified as a high-priority need in case of a radiological accident or nuclear terrorist attacks. A large-scale radiological incident would result in an immediate critical need to assess the radiation doses received by thousands of individuals. Casualties will be exposed to different doses and dose rates due to their geographical position and sheltering conditions, and dose rate is one of the principal factors that determine the biological consequences of a given absorbed dose. In these scenarios, high-throughput platforms are required to identify the biological dose in a large number of exposed individuals for clinical monitoring and medical treatment. The Rapid Automated Biodosimetry Tool (RABiT) is designed to be completely automated from the input of blood sample into the machine to the output of a dose estimate. The primary goal of this paper was to quantify the dose rate effects for RABiT-measured micronuclei in vitro in human lymphocytes. Blood samples from healthy volunteers were exposed in vitro to different doses of X-rays to acute and protracted doses over a period up to 24 h. The acute dose was delivered at similar to 1.03 Gy/min and the low dose rate exposure at similar to 0.31 Gy/min. The results showed that the yield of micronuclei decreases with decreasing dose rate starting at 2 Gy, whereas response was indistinguishable from that of acute exposure in the low dose region, up to 0.5 Gy. The results showed a linear-quadratic dose-response relationship for the occurrence of micronuclei for the acute exposure and a linear dose-response relationship for the low dose rate exposure.
机译:在辐射事故或核恐怖袭击的情况下,开发新的辐射生物剂量测定方法已被认为是当务之急。大规模的放射事件将导致迫切需要评估成千上万个人接受的辐射剂量。由于伤员的地理位置和庇护条件,伤亡者将面临不同的剂量和剂量率,剂量率是确定给定吸收剂量的生物学后果的主要因素之一。在这些情况下,需要高通量平台来识别大量暴露个体的生物剂量,以进行临床监测和医学治疗。快速自动生物剂量测定工具(RABiT)旨在从输入血液样本到机器到剂量估算输出完全自动化。本文的主要目标是量化人淋巴细胞中RABiT测量的微核的剂量率效应。在长达24小时的时间内,将健康志愿者的血液样本体外暴露于不同剂量的X射线,以急性和长期剂量照射。急性剂量以接近1.03 Gy / min的速度传递,低剂量率暴露以接近0.31 Gy / min的速度传递。结果表明,从2 Gy开始,微核的产量随剂量率的降低而降低,而在低剂量区域(直至0.5 Gy),其反应与急性暴露的反应无明显区别。结果表明,对于急性暴露,微核的发生具有线性-二次剂量响应关系,对于低剂量率暴露,具有线性剂量-响应关系。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号