首页> 外文期刊>Respiration: International Review of Thoracic Diseases >Feasibility and Accuracy of Molecular Testing in Specimens Obtained with Small Biopsy Forceps: Comparison with the Results of Surgical Specimens
【24h】

Feasibility and Accuracy of Molecular Testing in Specimens Obtained with Small Biopsy Forceps: Comparison with the Results of Surgical Specimens

机译:小型活检钳样本中分子检测的可行性和准确性:与手术样本结果的比较

获取原文
获取原文并翻译 | 示例
           

摘要

Background: During bronchoscopy, small biopsy forceps are increasingly used for the diagnosis of peripheral pulmonary lesions. However, it is unclear whether the formalin-fixed paraffin-embedded specimens sampled with the small biopsy forceps are suitable for the determination of genotypes which become indispensable for the management decision regarding patients with non-small cell lung cancer. Objectives: The aim of this study was to evaluate the feasibility and accuracy of molecular testing in the specimens obtained with 1.5-mm small biopsy forceps. Methods: We examined specimens in 91 patients, who were enrolled in our previous 3 studies on the usefulness of thin bronchoscopes and given a diagnosis of non-small cell lung cancer by bronchoscopy with the 1.5-mm biopsy forceps, and then underwent surgical resection. An experienced pathologist examined paraffin-embedded specimens obtained by bronchoscopic biopsy or surgical resection in a blind fashion on epidermal growth factor receptor (EGFR) mutations, anaplastic lymphoma kinase (ALK) rearrangements and KRAS mutations. Results: Twenty-five (27%), 2 (2%) and 5 (5%) patients had an EGFR mutation, ALK rearrangement and KRAS mutation, respectively, based on the results in surgical specimens. EGFR, ALK and KRAS testing with bronchoscopic specimens was feasible in 82 (90%), 86 (95%) and 83 (91%) patients, respectively. If molecular testing was feasible, the accuracy of EGFR, ALK and KRAS testing with bronchoscopic specimens for the results with surgical specimens was 98, 100 and 98%, respectively. Conclusion: The results of molecular testing in the formalin-fixed paraffin-embedded specimens obtained with the small forceps, in which the genotype could be evaluated, correlated well with those in surgically resected specimens. (C) 2015 S. Karger AG, Basel
机译:背景:在支气管镜检查期间,越来越多的小型活检钳被用于诊断周围性肺部病变。但是,尚不清楚用小型活检钳取样的福尔马林固定石蜡包埋的标本是否适合确定对于非小细胞肺癌患者的治疗决策而言必不可少的基因型。目的:本研究的目的是评估用1.5毫米小型活检钳获得的标本进行分子检测的可行性和准确性。方法:我们检查了91例患者的标本,这些患者参与了我们之前的3项关于细支气管镜的有效性的研究,并通过使用1.5毫米活检钳的支气管镜对非小细胞肺癌进行了诊断,然后进行了手术切除。一位经验丰富的病理学家检查了通过支气管镜活检或手术切除盲目方式获得的石蜡包埋标本的表皮生长因子受体(EGFR)突变,间变性淋巴瘤激酶(ALK)重排和KRAS突变。结果:根据手术标本的结果,分别有25名(27%),2(2%)和5(5%)患者出现EGFR突变,ALK重排和KRAS突变。用支气管镜标本进行EGFR,ALK和KRAS检测分别对82(90%),86(95%)和83(91%)患者可行。如果分子检测可行,则支气管镜标本进行EGFR,ALK和KRAS检测的手术标本的准确性分别为98%,100%和98%。结论:用小镊子在福尔马林固定石蜡包埋的标本中进行分子检测的结果可评估基因型,与手术切除标本的相关性很好。 (C)2015 S.Karger AG,巴塞尔

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号