首页> 外文期刊>Radiotherapy and oncology: Journal of the European Society for Therapeutic Radiology and Oncology >Analysis of interfractional set-up errors and intrafractional organ motions during IMRT for head and neck tumors to define an appropriate planning target volume (PTV)- and planning organs at risk volume (PRV)-margins.
【24h】

Analysis of interfractional set-up errors and intrafractional organ motions during IMRT for head and neck tumors to define an appropriate planning target volume (PTV)- and planning organs at risk volume (PRV)-margins.

机译:分析IMRT期间头颈部肿瘤的小节建立错误和小节内器官运动,以定义适当的计划目标体积(PTV)和以风险量(PRV)边界规划器官。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND AND PURPOSE: To analyze the interfractional set-up errors and intrafractional organ motions and to define appropriate planning target volume (PTV)- and planning organs at risk volume (PRV)-margins in intensity-modulated radiotherapy (IMRT) for head and neck tumors. PATIENTS AND METHODS: Twenty-two patients with head and neck or brain tumors who were treated with IMRT were enrolled. The set-up errors were defined as the displacements of the coordinates of bony landmarks on the beam films from those on the simulation films. The organ motions were determined as the displacements of the coordinates of the landmarks on the images recorded every 3 min for 15 min on the X-ray simulator from those on the initial image. RESULTS: The standard deviations (SDs) of the systematic set-up errors (Sigma-INTER) and organ motions (Sigma-intra) distributed with a range of 0.7-1.3 and 0.2-0.8 mm, respectively. The average of the SDs of the random set-up errors (sigma-INTER) and organ motions (sigma-intra) ranged from 0.7 to 1.6 mm and from 0.3 to 0.6 mm, respectively. Appropriate PTV-margins and PRV-margins for all the landmarks ranged from 2.0 to 3.6 mm and from 1.8 to 2.4 mm, respectively. CONCLUSIONS: We have adopted a PTV-margin of 5mm and a PRV-margin of 3mm for head and neck IMRT at our department.
机译:背景与目的:分析头位和颈部调强放疗(IMRT)中的分形建立误差和分形器官运动,并定义适当的计划目标体积(PTV)和计划器官处于危险量(PRV)的边缘肿瘤。患者和方法:招募了22例接受IMRT治疗的头颈部或脑部肿瘤患者。设置误差定义为光束胶片上的骨标的坐标与模拟胶片上的骨标的坐标的位移。器官运动被确定为在X射线模拟器上每3分钟记录15分钟的图像上的地标坐标相对于初始图像的位移。结果:系统设置误差(Sigma-INTER)和器官运动(Sigma-intra)的标准偏差(SDs)分别在0.7-1.3和0.2-0.8 mm范围内分布。随机设置误差(sigma-INTER)和器官运动(sigma-intra)的SD平均值分别为0.7至1.6 mm和0.3至0.6 mm。所有界标的适当PTV边距和PRV边距分别为2.0到3.6毫米和1.8到2.4毫米。结论:我们部门的头颈部IMRT采用了5mm的PTV间隔和3mm的PRV间隔。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号