首页> 外文期刊>Rapid Communications in Mass Spectrometry: RCM >A simplified protein precipitation/mixed-mode cation-exchange solid-phase extraction, followed by high-speed liquid chromatography/mass spectrometry, for the determination of a basic drug in human plasma
【24h】

A simplified protein precipitation/mixed-mode cation-exchange solid-phase extraction, followed by high-speed liquid chromatography/mass spectrometry, for the determination of a basic drug in human plasma

机译:简化的蛋白质沉淀/混合模式阳离子交换固相萃取,然后用高速液相色谱/质谱法测定人血浆中的基本药物

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A simplified protein precipitation/mixed-mode cation-exchange solid-phase extraction (PPT/SPE) procedure has been investigated. A mixture of acetonitrile and methanol along with formic acid was used to precipitate plasma proteins prior to selectively extracting the basic drug. After vortexing and centrifugation, the supernatants were directly loaded onto an unconditioned Oasis (R) MCX mu Elution 96-well extraction plate, where the protonated drug was retained on the negatively charged sorbent while interfering neutral lipids, steroids or other endogenous materials were washed away. Normal wash steps were deemed unnecessary and not used before sample elution. The sample extracts were analyzed under both conventional and high-speed liquid chromatography/tandem mass spectrometry (LC/MS/MS) conditions to examine the feasibility of the PPT/SPE procedure for human plasma sample clean-up. For the conventional LC/MS/MS method, chromatographic separation was achieved on a C18, 2.1 X 50 mm column with gradient elution (k' = 5.5). The mobile phase contained 0.1% formic acid in water and 0.1% formic acid in acetonitrile. For the high-speed LC/MS/MS method, chromatographic separation was achieved on a C18,2.1 X 10 mm guard column with gradient elution (k'= 2.2, Rt = 0.26 min). The mobile phase contained 0.1% formic acid in water and 0.001% trifluoroacetic acid in acetonitrile. Detection for both conventional and high-speed LC/MS/MS methods was by positive ion electrospray tandem mass spectrometry on a ThermoElectron Finnigan TSQ Quantum Ultra, where enhanced resolution (RP 2000; 0.2amu) was used for high-speed LC/MS/MS. The standard curve, ranging from 0.5 to 100 ng/mL, was fitted to a 1/x weighted quadratic regression model. This combined PPT/SPE procedure effectively eliminated time-consuming sorbent conditioning and wash steps, which are essential for a conventional mixed-mode SPE procedure, but retained the advantages of both PPT (removal of plasma proteins) and mixed-mode SPE (analyte selectivity). The validation results demonstrated that this PPT/SPE procedure was well suited for both conventional and high-speed LC/MS/MS analyses. In comparison with a conventional mixed-mode SPE procedure, the simplified PPT/SPE process provided comparable sample extract purity. This simple sample clean-up procedure can be applied to other basic compounds with minor modifications of PPT solvents. Copyright (c) 2006 John Wiley & Sons, Ltd.
机译:研究了简化的蛋白质沉淀/混合模式阳离子交换固相萃取(PPT / SPE)程序。在选择性提取碱性药物之前,使用乙腈和甲醇以及甲酸的混合物沉淀血浆蛋白。涡旋和离心后,将上清液直接上样到未经调节的Oasis(R)MCX mu Elution 96孔萃取板上,将质子化的药物保留在带负电荷的吸附剂上,同时洗去干扰中性脂质,类固醇或其他内源性物质。正常的洗涤步骤被认为是不必要的,并且在样品洗脱之前不使用。在常规和高速液相色谱/串联质谱(LC / MS / MS)条件下分析样品提取物,以检查PPT / SPE程序用于净化人血浆样品的可行性。对于传统的LC / MS / MS方法,在C18、2.1 X 50 mm色谱柱上采用梯度洗脱(k'= 5.5)进行色谱分离。流动相在水中含有0.1%的甲酸和在乙腈中含有0.1%的甲酸。对于高速LC / MS / MS方法,在C18,2.1 X 10 mm保护柱上通过梯度洗脱(k'= 2.2,Rt = 0.26分钟)进行色谱分离。流动相在水中含有0.1%的甲酸和在乙腈中含有0.001%的三氟乙酸。常规和高速LC / MS / MS方法的检测均通过ThermoElectron Finnigan TSQ Quantum Ultra上的正离子电喷雾串联质谱法进行,其中高分辨率(RP 2000; 0.2amu)用于高速LC / MS /多发性硬化症。将标准曲线的范围从0.5到100 ng / mL拟合到1 / x加权二次回归模型。这种结合的PPT / SPE程序有效地消除了费时的吸附剂调节和洗涤步骤,这对于常规的混合模式SPE程序而言必不可少,但保留了PPT(去除血浆蛋白)和混合模式SPE(分析物选择性)的优势)。验证结果表明,该PPT / SPE程序非常适合常规和高速LC / MS / MS分析。与传统的混合模式SPE程序相比,简化的PPT / SPE工艺可提供相当的样品提取纯度。这种简单的样品净化程序可以应用于对PPT溶剂稍加修改的其他碱性化合物。版权所有(c)2006 John Wiley&Sons,Ltd.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号