Towards a universal product ion mass spectral library - reproducibility of product ion spectra across eleven different mass spectrometers

机译:迈向通用的产物离子质谱库-十一种不同质谱仪上产物离子谱的重现性

获取原文
获取原文并翻译 | 示例
           

摘要

Product ion spectra produced by collision-induced dissociation (CID) in tandem mass spectrometry experiments can differ markedly between instruments. There have been a number of attempts to standardise the production of product ion spectra; however, a consensus on the most appropriate approach to the reproducible production of spectra has yet to be reached. We have previously reported the comparison of product ion spectra on a number of different types of instruments - a triple quadrupole, two ion traps and a Fourier transform ion cyclotron resonance mass spectrometer (Bristow AWT, Webb KS, Lubben AT, Halket JM. Rapid Commun. Mass Spectrom. 2004; 18: 1). The study showed that a high degree of reproducibility was achievable. The goal of this study was to improve the comparability and reproducibility of CID product ion mass spectra produced in different laboratories and using different instruments. This was carried out experimentally by defining a spectral calibration point on each mass spectrometer for product ion formation. The long-term goal is the development of a universal (instrument independent) product ion mass spectral library for the identification of unknowns. The spectra of 48 compounds have been recorded on eleven mass spectrometers: six ion traps, two triple quadrupoles, a hybrid triple quadrupole, and two quadrupole time-of-flight instruments. Initially, 4371 spectral comparisons were carried out using the data from eleven instruments and the degree of reproducibility was evaluated. A blind trial has also been carried out to assess the reproducibility of spectra obtained during LC/MS/MS. The results suggest a degree of reproducibility across all instrument types using the tuning point technique. The reproducibility of the product ion spectra is increased when comparing the tandem in time type instruments and the tandem in space instruments as two separate groups. This may allow the production of a more limited, yet useful, screening library for LC/MS/MS identification using instruments of the same type from different manufacturers. Copyright (C) 2008 John Wiley & Sons, Ltd.
机译:在串联质谱实验中,由碰撞诱导解离(CID)产生的产物离子谱在仪器之间可能存在显着差异。已经进行了许多尝试来标准化产物离子光谱的产生。然而,关于最合适的可重复产生光谱的方法尚未达成共识。我们以前曾报道过在许多不同类型的仪器上对产物离子光谱的比较-三重四极杆,两个离子阱和傅立叶变换离子回旋共振质谱仪(Bristow AWT,Webb KS,Lubben AT,Halket JM.Rapid Commun质谱.2004; 18:1)。研究表明,可以实现高度的可重复性。这项研究的目的是提高在不同实验室和使用不同仪器产生的CID产物离子质谱图的可比性和重现性。这是通过在每个质谱仪上定义用于产物离子形成的光谱校准点来进行的。长期目标是开发通用的(与仪器无关)产物离子质谱库,用于鉴定未知物。在11个质谱仪上记录了48种化合物的光谱:六个离子阱,两个三重四极杆,一个混合三重四极杆和两个四极飞行时间仪器。最初,使用来自11种仪器的数据进行了4371次光谱比较,并评估了可重复性程度。还进行了盲法试验,以评估在LC / MS / MS过程中获得的光谱的再现性。结果表明使用调谐点技术可在所有类型的仪器上实现一定程度的可重复性。当将时间型仪器中的串联和空间仪器中的串联作为两个单独的组进行比较时,产物离子光谱的重现性得到了提高。这可能允许使用来自不同制造商的相同类型的仪器来生产用于LC / MS / MS鉴定的更有限但更有用的筛选库。版权所有(C)2008 John Wiley&Sons,Ltd.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号