Using a single platform of a triple-quadrupole mass spectrometer equipped with enhanced resolution and accurate mass capabilities, a strategy for metabolite identification of a drug in a biological matrix has been demonstrated. The strategy is based on first screening for metabolites via neutral loss and precursor ion scan schemes, devised as the result of the product ion spectrum of a matrix-free standard of the drug. The accurate masses of the precursor ions identified via the two scan schemes plus the precursor ions of structurally likely metabolites are then determined by enhanced resolution, accurate mass (AM) selected ion monitoring (SIM). The identities of the metabolites are further established by determining the accurate masses of the product ions via enhanced resolution AM selected reaction monitoring (SRM). The feasibility of the strategy was demonstrated using a liver microsome incubation sample of nefazodone, an antidepressant drug. The neutral loss and precursor ion screening runs were able to identify most of the metabolites of nefazodone. The subsequent SIM and SRM experiments gave mass accuracy of better than +/-0.003 u for the masses of the precursor and product ions of nefazodone and all the metabolites. The ability to perform metabolite screening by using the scan features followed by accurate mass determinations on the same instrument is an attractive feature of using a triple-quadrupole mass spectrometer with enhanced resolution and accurate mass capability. Copyright (C) 2003 John Wiley Sons, Ltd. [References: 7]
机译:使用装备有增强的分辨率和精确质量功能的三重四极杆质谱仪的单个平台,已证明了在生物基质中鉴定药物代谢物的策略。该策略基于通过中性丢失和前体离子扫描方案对代谢物的首次筛选,该方案是根据无基质药物标准品的产物离子光谱设计的。然后通过增强的分辨率,精确质量(AM)选择离子监测(SIM)确定通过两种扫描方案确定的前体离子的准确质量以及结构上可能的代谢物的前体离子。通过提高分辨率的AM选择反应监测(SRM)确定产物离子的准确质量,可以进一步确定代谢物的身份。使用抗抑郁药奈法唑酮的肝微粒体孵育样品证明了该策略的可行性。中性损失和前体离子筛选运行能够鉴定奈法唑酮的大部分代谢产物。随后的SIM和SRM实验对奈法唑酮和所有代谢产物的前体和产物离子的质量提供了优于+/- 0.003 u的质量精度。通过使用扫描功能执行代谢物筛选,然后在同一仪器上进行精确质量测定的能力是使用具有增强的分辨率和精确质量功能的三重四极杆质谱仪的一项吸引人的功能。版权所有(C)2003 John Wiley Sons,Ltd. [参考:7]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号