首页> 外文期刊>Rapid Communications in Mass Spectrometry: RCM >Quadrupole time-of-flight versus triple-quadrupole mass spectrometry for the determination of non-steroidal antiinflammatory drugs in surface water by liquid chromatography/tandem mass spectrometry
【24h】

Quadrupole time-of-flight versus triple-quadrupole mass spectrometry for the determination of non-steroidal antiinflammatory drugs in surface water by liquid chromatography/tandem mass spectrometry

机译:四极杆飞行时间与三重四极杆质谱的液相色谱/串联质谱法测定地表水中的非甾体类抗炎药

获取原文
获取原文并翻译 | 示例
       

摘要

A triple-quadrupole instrument and a hybrid quadrupole/time-of-flight (TOF) mass spectrometer were compared for the determination of pharmaceutical compounds in water samples. The drugs investigated were the analgesics Ibuprofen, Fenoprofen, Ketoprofen, Naproxen, and Diclofenac. The recently introduced Q2-pulsing function, which enhances the transmission of fragment ions of a selected m/z window from the collision cell into the TOF analyzer, improved the sensitivity of product ion scans on the quadrupole/TOF instrument. The selectivity is much better on quadrupole/TOF systems than on triple quadrupoles because the high resolving power of the reflectron-TOF mass analyzer permits high-accuracy fragment ion selection. This minimizes interferences from environmental matrices and allows acquisition of full spectra for selected analytes with better signal-to-noise characteristics than comparable spectra obtained with a scanned quadrupole. The qualitative information obtained (mass accuracy, resolution and full-scan spectra) by hybrid quadrupole/TOF mass spectrometry allows a more certain identification of analytes in environmental matrices at trace levels. Sample enrichment of water samples was achieved by a solid-phase extraction procedure. Average recoveries for loading 1 L of samples varied from 88 to 110%, and the quantification limits were less than 1.2 ng/L for the triple-quadrupole instrument (in MRM mode) and less than 3 ng/L for the quadrupole/TOF instrument. Copyright (C) 2003 John Wiley Sons, Ltd. [References: 25]
机译:比较了三重四极杆仪器和混合型四重极/飞行时间(TOF)质谱仪,用于测定水样中的药物化合物。研究的药物为止痛药布洛芬,非诺洛芬,酮洛芬,萘普生和双氯芬酸。最近引入的Q2脉冲功能增强了所选m / z窗口中的碎片离子从碰撞室到TOF分析仪的传输,提高了四极杆/ TOF仪器上产物离子扫描的灵敏度。在四极杆/ TOF系统上,其选择性要比在三重四极杆系统上好得多,因为反射电子-TOF质量分析仪的高分辨能力允许高精度碎片离子的选择。这样可以最大程度地减少来自环境基质的干扰,并可以获取比使用扫描四极杆获得的可比光谱更好的信噪比特性的选定分析物的全光谱。通过混合四极杆/ TOF质谱仪获得的定性信息(质量准确度,分辨率和全扫描光谱)可以更确定地鉴定痕量水平的环境基质中的分析物。水样品的样品富集通过固相萃取程序实现。加载1 L样品的平均回收率从88%到110%不等,三重四极杆仪器(在MRM模式下)的定量限小于1.2 ng / L,四极杆/ TOF仪器小于3 ng / L 。版权所有(C)2003 John Wiley Sons,Ltd. [引用:25]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号