首页> 外文期刊>Radiology >Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight.
【24h】

Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight.

机译:对比剂注射持续时间和速率对动态CT的主动脉峰时间和峰增强的影响,动态CT涉及根据患者体重定制剂量的注射方案。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To investigate the effect of duration and rate of contrast material injection on aortic peak time and peak enhancement in an injection protocol in which the contrast material dose is adjusted according to patient weight. MATERIALS AND METHODS: One hundred ninety-nine patients were randomly divided into three groups in which the fixed duration of contrast material injection was 25 seconds (group A) or 35 seconds (group B) or the fixed injection rate was 4.0 mL/sec (group C). Computed tomography (CT) at the L3 vertebral level was performed before and after contrast material injection. Aortic peak time, aortic peak enhancement, and period when aortic enhancement is 200 HU or greater (T200) were calculated. The Pearson product-moment correlation coefficient (r) was used to investigate relationships between patient weight and aortic peak time, aortic peak enhancement, and T200 in each group. RESULTS: A significant correlation between aortic peak time and patient weight (r = 0.91, P <.001) was observed in group C. No significant correlations between patient weight and aortic peak time were observed in group A (r = 0.16, P =.21) or B (r = -0.05, P =.69). A significant inverse correlation between aortic peak enhancement and patient weight (r = -0.70, P <.001) was observed in group C. No significant correlations between patient weight and aortic peak enhancement were observed in group A (r = 0.09, P =.48) or B (r = 0.10, P =.41). A significant correlation between T200 and patient weight (r = 0.72, P <.001) was observed in group C. No significant correlations between patient weight and T200 were observed in group A (r = 0.12, P =.34) or B (r = 0.001, P =.99). CONCLUSION: Aortic peak time, aortic peak enhancement, and T200 were closely related to injection duration in the protocol with contrast material dose determined according to patient weight.
机译:目的:在根据患者体重调整造影剂剂量的注射方案中,研究造影剂注射的持续时间和速率对主动脉峰时间和峰增强的影响。材料与方法:199例患者随机分为三组,分别将造影剂的固定注射时间设为25秒(A组)或35秒(B组)或固定注射速率为4.0 mL / sec( C组)。在注射对比剂之前和之后,在L3椎骨水平进行计算机断层扫描(CT)。计算主动脉峰值时间,主动脉峰值增强和主动脉增强为200 HU或更大时的周期(T200)。皮尔逊乘积矩相关系数(r)用于研究患者体重与主动脉峰值时间,主动脉峰值增强和T200之间的关系。结果:在C组中观察到主动脉峰值时间与患者体重之间存在显着相关性(r = 0.91,P <.001)。在A组中未观察到患者体重与主动脉峰值时间之间存在显着相关性(r = 0.16,P = .21)或B(r = -0.05,P = .69)。在C组中观察到主动脉峰值增强与患者体重之间存在显着的负相关(r = -0.70,P <.001)。在A组中未观察到患者体重与主动脉峰值增强之间存在显着的相关性(r = 0.09,P = .48)或B(r = 0.10,P = .41)。在C组中观察到T200与患者体重之间存在显着相关性(r = 0.72,P <.001)。在A组(r = 0.12,P = .34)或B组中未观察到患者体重与T200之间的显着相关性(r = 0.12,P = .34)。 r = 0.001,P = .99)。结论:主动脉峰时间,主动脉峰增强和T200与方案中的注射时间密切相关,造影剂剂量根据患者体重确定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号