首页> 外文期刊>Radiology >Comparison of Two-dimensional synthesized Mammograms versus Original Digital Mammograms alone and in combination with Tomosynthesis images
【24h】

Comparison of Two-dimensional synthesized Mammograms versus Original Digital Mammograms alone and in combination with Tomosynthesis images

机译:二维合成乳腺X线照片与原始数字乳腺X线照片以及结合断层合成图像的比较

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Purpose: To assess interpretation performance and radiation dose when two-dimensional synthesized mammography (SM) images versus standard full-field digital mammography (FFDM) images are used alone or in combination with digital breast tomosynthesis images. Materials and Methods: A fully crossed, mode-balanced multicase (n = 123), multireader (n = 8), retrospective observer performance study was performed by using deidentified images acquired between 2008 and 2011 with institutional review board approved, HIPAA-compliant protocols, during which each patient signed informed consent. The cohort included 36 cases of biopsy-proven cancer, 35 cases of biopsy-proven benign lesions, and 52 normal or benign cases (Breast Imaging Reporting and Data System [BI-RADS] score of 1 or 2) with negative 1-year follow-up results. Accuracy of sequentially reported probability of malignancy ratings and seven-category forced BI-RADS ratings was evaluated by using areas under the receiver operating characteristic curve (AUCs) in the random-reader analysis. Results: Probability of malignancy-based mean AUCs for SM and FFDM images alone was 0.894 and 0.889, respectively (difference, 20.005; 95% confidence interval [CI]: 20.062, 0.054; P =.85). Mean AUC for SM with tomosynthesis and FFDM with tomosynthesis was 0.916 and 0.939, respectively (difference, 0.023; 95% CI: 20.011, 0.057; P =.19). In terms of the reader-specific AUCs, five readers performed better with SM alone versus FFDM alone, and all eight readers performed better with combined FFDM and tomosynthesis (absolute differences from 0.003 to 0.052). Similar results were obtained by using a nonparametric analysis of forced BI-RADS ratings. Conclusion: SM alone or in combination with tomosynthesis is comparable in performance to FFDM alone or in combination with tomosynthesis and may eliminate the need for FFDM as part of a routine clinical study.
机译:目的:评估单独使用二维合成乳房X线摄影(SM)图像与标准全场数字乳房X线摄影(FFDM)图像或与乳房X线断层合成图像结合使用时的解释性能和辐射剂量。资料和方法:采用2008年至2011年之间获得的身份不明图像,经过机构审查委员会批准,符合HIPAA要求的协议,进行了完全交叉,模式平衡的多案例(n = 123),多阅读器(n = 8),回顾性观察者性能研究。 ,在此期间每个患者签署知情同意书。该队列包括36例经活检证实为癌症的病例,35例经活检证实为良性病变的病例以及52例正常或良性病例(乳腺成像报告和数据系统[BI-RADS]评分为1或2),且随访1年为阴性结果。通过在随机读取器分析中使用接收器工作特性曲线(AUC)下的面积,评估了顺序报告的恶性评级和七类强制BI-RADS评级的准确性。结果:仅基于SM和FFDM图像的基于恶性肿瘤的平均AUC的概率分别为0.894和0.889(差异,20.005; 95%置信区间[CI]:20.062,0.054; P = .85)。带有断层合成的SM和具有断层合成的FFDM的平均AUC分别为0.916和0.939(差异,0.023; 95%CI:20.011,0.057; P = .19)。就读者特定的AUC而言,单独使用SM的五个阅读器比单独使用FFDM的阅读器表现更好,而使用FFDM和层析合成的所有八个阅读器都表现更好(绝对差异从0.003到0.052)。通过使用强制BI-RADS评级的非参数分析获得了相似的结果。结论:SM单独或与层析合成相结合的性能可与FFDM单独或与层析合成相结合的性能,并且可以消除常规临床研究中对FFDM的需求。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号