The X-ray source or focal radiation is one of the factors that can degrade the conformal field edge in stereotactic body radiotherapy. For that reason, it is very important to estimate the total focal radiation profiles of linear accelerators, which consists of X-ray focal-spot radiation and extra-focal radiation profiles. Our purpose in this study was to propose an experimental method for estimating the focal-spot and extra-focal radiation profiles of linear accelerators based on triple Gaussian functions. We measured the total X-ray focal radiation profiles of the accelerators by moving a slit in conjunction with a photon field p-type silicon diode. The slit width was changed so that the extra-focal radiation could be optimally included in the total focal radiation. The total focal radiation profiles of an accelerator at 4-MV and 10-MV energies were approximated with a combination of triple Gaussian functions, which correspond to the focal-spot radiation, extra-focal radiation, and radiation transmitted through the slit assembly. As a result, the ratios of the Gaussian peak value of the extra-focal radiation to that of the focal spot for 4 and 10 MV were 0.077 and 0.159, respectively. The peak widths of the focal-spot and extra-focal radiation profiles were 0.57 and 25.0 mm for 4 MV, respectively, and 0.60 and 22.0 mm for 10 MV, respectively. We concluded that the proposed focal radiation profile model based on the triple Gaussian functions may be feasible for estimating the X-ray focal-spot and extra-focal radiation profiles.
机译:X射线源或聚焦辐射是可降低立体定向身体放射治疗中保形场边缘的因素之一。因此,估算线性加速器的总聚焦辐射图非常重要,它由X射线焦点辐射和焦外辐射图组成。我们在这项研究中的目的是提出一种基于三重高斯函数估算线性加速器的焦点和焦点外辐射曲线的实验方法。我们通过与光子场p型硅二极管一起移动狭缝来测量加速器的总X射线聚焦辐射曲线。更改了缝隙宽度,以便可以将焦点外辐射最佳地包含在总焦点辐射中。加速器在4-MV和10-MV能量下的总聚焦辐射曲线是通过三重高斯函数的组合来估算的,这三者分别对应于焦点辐射,焦点外辐射和通过狭缝组件传输的辐射。结果,对于4和10MV,焦外辐射的高斯峰值与焦点的高斯比率之比分别为0.077和0.159。对于4 MV,焦斑和焦外辐射曲线的峰宽分别为0.57和25.0 mm,对于10 MV,峰宽分别为0.60和22.0 mm。我们得出的结论是,基于三重高斯函数提出的聚焦辐射轮廓模型对于估算X射线焦点和聚焦外辐射轮廓可能是可行的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号